Glossary Terms (Simple List)
-
Aerobic Microorganism
A microorganism that utilizes oxygen as the final electron acceptor during metabolism; a microorganism that will grow primarily in the presence of oxygen. For the purpose of this report, this definition encompasses facultative anaerobes. (TR22) (TR62)
-
Aggregation
Clumping of proteins, viruses, or bacteria that may arise from several mechanisms and may be classified in numerous ways, including soluble/insoluble, covalent/noncovalent, reversible/irreversible, and native/denatured. (TR47)
-
Air Detector
A moist heat sterilization process that operates at a controlled pressure greater than saturated steam pressure and typically uses compressed air to bring the chamber to the desired pressure. (TR01) (TR48)
-
Air Overpressure Sterilization Process
A moist heat sterilization process that operates at a controlled pressure greater than saturated steam pressure and typically uses compressed air to bring the chamber to the desired pressure. (TR01) (TR48)
-
Air Removal Test
A test used to evaluate air removal and steam penetration in an empty sterilizer that is used for porous/hard goods load sterilization (e.g., Bowie-Dick Test, DART, Lantor Cube, Browns’ Test). (TR01) (TR 48)
-
Air Shower
A device fitted to a BFS machine which provides, at a minimum, a continuous flow of Grade A quality air supply over the filling needles and the point-of-fill. The air shower is also known as a nozzle shroud in shuttle type machines. (TR77)
-
Airborne Particulate Count (Total Particulate Count)
The total number of particles of a specific size per unit volume of air. (TR13)
-
Airborne Viable Particulate Count (Total Airborne Aerobic Microbial Count)
The total number of particles of a specific size per unit volume of air. (TR13)
-
Airlock
A room that controls the airflow between two rooms of different classification. (TR 70)
-
Alert Level
An established microbial or nonviable particle level giving early warning of potential drift from normal operating conditions; not necessarily grounds for definitive corrective action but typically requires follow-up investigation. (TR13) (TR22) (TR69)
An established level that, when exceeded, is giving an early warning of a potential drift from normal operating conditions; while not necessarily grounds for definitive corrective action, it typically requires follow-up review. (TR 60)
An established microbial or nonviable particle level giving early warning of potential drift from normal operating conditions; not necessarily grounds for definitive corrective action, but typically requires follow-up investigation (3, 4, 7). (TR88)