PDA Technical Reports are highly valued membership benefits because they offer expert guidance and opinions on important scientific and regulatory topics and are used as essential references by industry and regulatory authorities around the world. These reports include terms which explain the material and enhance the reader’s understanding.

The database presented here includes the glossary terms from all current technical reports. The database is searchable by keyword, topic, or by technical report. Each definition provided includes a link to the source technical report within the  PDA Technical Report Portal.

(Please select "All" to restart a filtered Search)

  • All
  • 0
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • A
  • B
  • C
  • D
  • E
  • F
  • G
  • H
  • I
  • J
  • K
  • L
  • M
  • N
  • O
  • P
  • Q
  • R
  • S
  • T
  • U
  • V
  • W
  • X
  • Y
  • Z
Acceptance Criteria
Numerical limits, ranges, or other suitable measures for acceptance of test results. (TR 14) (TR 29) (TR 38) (TR 64) Numerical limits, ranges, or other suitable measures for acceptance of test results. Exceeding the acceptable range for a critical parameter during subsequent validation studies may result in questionable product quality that would require initiation of an investigation. Exceeding the operating range should be documented and explained in the validation report and evaluated for validation study impact. (TR 42) The pre-defined specifications, standards or ranges that must be met under stated test conditions. (TR 48) Numerical limits, ranges, or other suitable measures for acceptance of the results of analytical method validation that is satisfied to determine suitability of test method performance.(TR 57) (TR 69) (TR 72) (TR 74) The criteria that a system or component must satisfy in order to be accepted by a user or other authorized entity. (TR 54-5) Numerical limits, ranges, or other suitable measures for acceptance of the results of analytical procedures which the drug substance or drug product or materials at other stages of their manufacture should meet (16). Exceeding the acceptable range for a critical parameter during subsequent validation studies may result in questionable product quality that would require initiation of an investigation and possible batch rejection. (TR60)
Source:
Design of Experiments (DOE)
A method for carrying out carefully planned experiments on a process. Usually, DoE involves a series of experiments that initially involves evaluating many variables and then focuses on a few critical ones. (TR54-4) A structured, organized method for determining the relationship between factors affecting an assay and output of that assay. (TR57) (TR57-2) (TR74) A structured, organized method for determining the relationship between factors affecting a process and the output of that process (8). (TR60)
Source:
Drug Product (DP)
A pharmaceutical product type that contains a drug substance, generally, in association with excipients. [Synonym: Dosage Form; Finished Product] (TR57)(TR14)(TR42) A finished dosage form (e.g., tablet, capsule, or solution) that contains a drug substance, generally, but not necessarily, in association with one or more other ingredients.(TR38) (TR67) (TR88) The dosage form in the final immediate packaging intended for marketing.(TR60)(TR82)
Source:
Drug Substance (DS)
The active ingredient that is subsequently formulated with excipients to produce the drug product. It can be composed of the desired product, product-related substances, and product- and process-related impurities. It may also contain excipients, including buffers and other components. [Synonyms: bulk drug substance, bulk material, active pharmaceutical ingredient (API)] (TR14) (TR57) (TR74) (TR60) Active pharmaceutical ingredient in a drug product that is responsible for that product’s therapeutic activity.(TR67) (TR82) (TR88) See Active Pharmaceutical Ingredient (API). (TR56)
Source: