PDA Technical Reports are highly valued membership benefits because they offer expert guidance and opinions on important scientific and regulatory topics and are used as essential references by industry and regulatory authorities around the world. These reports include terms which explain the material and enhance the reader’s understanding.

The database presented here includes the glossary terms from all current technical reports. The database is searchable by keyword, topic, or by technical report. Each definition provided includes a link to the source technical report within the  PDA Technical Report Portal.

(Please select "All" to restart a filtered Search)

  • All
  • 0
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • A
  • B
  • C
  • D
  • E
  • F
  • G
  • H
  • I
  • J
  • K
  • L
  • M
  • N
  • O
  • P
  • Q
  • R
  • S
  • T
  • U
  • V
  • W
  • X
  • Y
  • Z
Acceptance Criteria
Numerical limits, ranges, or other suitable measures for acceptance of test results. (TR 14) (TR 29) (TR 38) (TR 64) Numerical limits, ranges, or other suitable measures for acceptance of test results. Exceeding the acceptable range for a critical parameter during subsequent validation studies may result in questionable product quality that would require initiation of an investigation. Exceeding the operating range should be documented and explained in the validation report and evaluated for validation study impact. (TR 42) The pre-defined specifications, standards or ranges that must be met under stated test conditions. (TR 48) Numerical limits, ranges, or other suitable measures for acceptance of the results of analytical method validation that is satisfied to determine suitability of test method performance.(TR 57) (TR 69) (TR 72) (TR 74) The criteria that a system or component must satisfy in order to be accepted by a user or other authorized entity. (TR 54-5) Numerical limits, ranges, or other suitable measures for acceptance of the results of analytical procedures which the drug substance or drug product or materials at other stages of their manufacture should meet (16). Exceeding the acceptable range for a critical parameter during subsequent validation studies may result in questionable product quality that would require initiation of an investigation and possible batch rejection. (TR60)
Source:
Action Limit
An internal (in-house) value used to assess the consistency of the process. The cause of the excursion should be investigated and documented and corrective action is generally required. Action limits are not specifications. (TR42) An established internal (in-house) data-based value which is part of the control strategy and used to assess the consistency of the manufacturing process. An action limit excursion result in an investigation, identification of recovered isolates, root-cause analysis, assessment of a systemic failure and impact on product quality and patient safety. (TR69) An established internal (in-house) data-based value that is part of the control strategy and used to assess the consistency of the manufacturing process. An action limit excursion result in an investigation, identification of recovered isolates, root-cause analysis, assessment of a systemic failure and impact on product quality and patient safety. (TR74) A limit that, when exceeded, indicates a process is outside of its normal operating range. A response to such an excursion should involve a documented investigation and corrective actions based on the results of that investigation. (TR60)
Source:
Alert Level
An established microbial or nonviable particle level giving early warning of potential drift from normal operating conditions; not necessarily grounds for definitive corrective action but typically requires follow-up investigation. (TR13) (TR22) (TR69) An established level that, when exceeded, is giving an early warning of a potential drift from normal operating conditions; while not necessarily grounds for definitive corrective action, it typically requires follow-up review. (TR 60) An established microbial or nonviable particle level giving early warning of potential drift from normal operating conditions; not necessarily grounds for definitive corrective action, but typically requires follow-up investigation (3, 4, 7). (TR88)
Source: