PDA Technical Reports are highly valued membership benefits because they offer expert guidance and opinions on important scientific and regulatory topics and are used as essential references by industry and regulatory authorities around the world. These reports include terms which explain the material and enhance the reader’s understanding.

The database presented here includes the glossary terms from all current technical reports. The database is searchable by keyword, topic, or by technical report. Each definition provided includes a link to the source technical report within the  PDA Technical Report Portal.

(Please select "All" to restart a filtered Search)

  • All
  • 0
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • A
  • B
  • C
  • D
  • E
  • F
  • G
  • H
  • I
  • J
  • K
  • L
  • M
  • N
  • O
  • P
  • Q
  • R
  • S
  • T
  • U
  • V
  • W
  • X
  • Y
  • Z
Acceptance Criteria
Numerical limits, ranges, or other suitable measures for acceptance of test results. (TR 14) (TR 29) (TR 38) (TR 64) Numerical limits, ranges, or other suitable measures for acceptance of test results. Exceeding the acceptable range for a critical parameter during subsequent validation studies may result in questionable product quality that would require initiation of an investigation. Exceeding the operating range should be documented and explained in the validation report and evaluated for validation study impact. (TR 42) The pre-defined specifications, standards or ranges that must be met under stated test conditions. (TR 48) Numerical limits, ranges, or other suitable measures for acceptance of the results of analytical method validation that is satisfied to determine suitability of test method performance.(TR 57) (TR 69) (TR 72) (TR 74) The criteria that a system or component must satisfy in order to be accepted by a user or other authorized entity. (TR 54-5) Numerical limits, ranges, or other suitable measures for acceptance of the results of analytical procedures which the drug substance or drug product or materials at other stages of their manufacture should meet (16). Exceeding the acceptable range for a critical parameter during subsequent validation studies may result in questionable product quality that would require initiation of an investigation and possible batch rejection. (TR60)
Source:
Development Reports
Documentation and description of work done during the early phases of development. The goal is to document information about the way the process works and to document why key choices were made in selecting the specifics of the process (e.g., flow rate or temperature). These documents can serve as a reference during investigations of discrepancies and during the design of specific Validation and characterization studies.(TR14) (TR 42) Documentation and description of work done during the early phases of development (Stage 1). The goal is to document information about the way the process works and to document why key choices were made in selecting the specifics of the process (e.g., flow rate or temperature). These documents can serve as a reference during investigations of deviations and during the design of specific validation and process characterization studies.(TR60)
Source:
Drug Product (DP)
A pharmaceutical product type that contains a drug substance, generally, in association with excipients. [Synonym: Dosage Form; Finished Product] (TR57)(TR14)(TR42) A finished dosage form (e.g., tablet, capsule, or solution) that contains a drug substance, generally, but not necessarily, in association with one or more other ingredients.(TR38) (TR67) (TR88) The dosage form in the final immediate packaging intended for marketing.(TR60)(TR82)
Source:
Installation Qualification (IQ)
Documented verification that the equipment or systems, as installed or modified, comply with the approved design, the manufacturer’s recommendations, and/or user requirements. (TR14) (TR42) (TR48) (TR61) (TR64) The documented verification that the facilities, systems and equipment, as installed or modified, comply with the approved design and the manu­facturer’s recommendations. (TR54-5) Documented verification that the equipment or systems, as installed or modified, comply with the approved design, the manufacturer’s recommendations, and/or user requirements (17). (TR60)
Source:
Process Validation Master Plan (PVMP)
A document that defines the process validation scope and rationale and that contains the list of process validation studies to be performed (Synonym: Validation Master Plan). (TR42) (TR60) The plan that documents rationale for the approach to validation and lists all systems and their validation status. (Note: The VMP can be used to document the rationale for number of monitors and revalidation frequency, as well as other system justifications). (TR52)
Source: