PDA Technical Reports are highly valued membership benefits because they offer expert guidance and opinions on important scientific and regulatory topics and are used as essential references by industry and regulatory authorities around the world. These reports include terms which explain the material and enhance the reader’s understanding.

The database presented here includes the glossary terms from all current technical reports. The database is searchable by keyword, topic, or by technical report. Each definition provided includes a link to the source technical report within the  PDA Technical Report Portal.

(Please select "All" to restart a filtered Search)

  • All
  • 0
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • A
  • B
  • C
  • D
  • E
  • F
  • G
  • H
  • I
  • J
  • K
  • L
  • M
  • N
  • O
  • P
  • Q
  • R
  • S
  • T
  • U
  • V
  • W
  • X
  • Y
  • Z
Operational Qualification (OQ)
Documented verification that the equipment or systems, as installed or modified, perform as intended throughout the anticipated operating ranges. (TR14) (TR61) (TR64) (TR72) The documented verification that the facilities, systems and equipment, as installed or modified, perform as intended throughout the anticipated operating ranges. (TR54-5) Documented verification that the equipment or systems, as installed or modified, perform as intended throughout the anticipated operating ranges (17). (TR60-3)

Source:

Failure Mode and Effects Analysis (FMEA)
A method of assessing and evaluating risk. (TR44) A systematic method for identifying, analyzing, prioritizing and documenting potential failure modes, their effects on system, product and process performance, and the possible causes of failure in order to prevent defects from occurring. (TR54) (TR54-2) (TR54-3) (TR54-4) (TR74) (TR54-5) A tool for analyzing processes or systems to evaluate all operating steps in order to identify and assess the risk associated with any potential failures. (TR65) An analytical technique that results in a rankordered list of concerns to take action on. (TR72)

Source:

Emissivity (?)
The emissivity of the surface of a material is its effectiveness in emitting energy as thermal radiation. This is measured between 0 (zero) and 1 (one); 0 having the ability to reflect all energy, and 1 allowing all energy to pass through it. Glass, for example, has emissivity of 0.91 (smooth, uncoated); aluminium foil has emissivity of 0.03. (TR72)

Source:

Active Temperature Controlled System
Actively powered system that uses electricity or other fuel source to maintain a temperaturecontrolled environment inside an insulated enclosure under thermostatic regulation (e.g., cold room, refrigerator, temperature-controlled truck, refrigerated ocean or air container). (TR 72) (TR64)

Source:

Active Systems
Systems with active temperature control (e.g., air/sea freight containers, refrigerated trucks/cars). (TR39) System with active temperature control. It makes use of electricity or fuel for the compressor to maintain temperature. Examples include refrigerated trucks, temperature-controlled ocean containers, and active ULDs. (TR58) Actively powered system that uses electricity or other fuel source to maintain a temperaturecontrolled environment inside an insulated enclosure under thermostatic regulation (e.g., cold room, refrigerator, temperature-controlled truck, refrigerated ocean or air container). (TR64) (TR72) (Synonym: Active Temperature Controlled System)

Source:

Acceptance Criteria
Numerical limits, ranges, or other suitable measures for acceptance of test results. (TR 14) (TR 29) (TR 38) (TR 64) Numerical limits, ranges, or other suitable measures for acceptance of test results. Exceeding the acceptable range for a critical parameter during subsequent validation studies may result in questionable product quality that would require initiation of an investigation. Exceeding the operating range should be documented and explained in the validation report and evaluated for validation study impact. (TR 42) The pre-defined specifications, standards or ranges that must be met under stated test conditions. (TR 48) Numerical limits, ranges, or other suitable measures for acceptance of the results of analytical method validation that is satisfied to determine suitability of test method performance.(TR 57) (TR 69) (TR 72) (TR 74) The criteria that a system or component must satisfy in order to be accepted by a user or other authorized entity. (TR 54-5) Numerical limits, ranges, or other suitable measures for acceptance of the results of analytical procedures which the drug substance or drug product or materials at other stages of their manufacture should meet (16). Exceeding the acceptable range for a critical parameter during subsequent validation studies may result in questionable product quality that would require initiation of an investigation and possible batch rejection. (TR60)

Source: