PDA Technical Reports are highly valued membership benefits because they offer expert guidance and opinions on important scientific and regulatory topics and are used as essential references by industry and regulatory authorities around the world. These reports include terms which explain the material and enhance the reader’s understanding.

The database presented here includes the glossary terms from all current technical reports. The database is searchable by keyword, topic, or by technical report. Each definition provided includes a link to the source technical report within the  PDA Technical Report Portal.

(Please select "All" to restart a filtered Search)

  • All
  • 0
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • A
  • B
  • C
  • D
  • E
  • F
  • G
  • H
  • I
  • J
  • K
  • L
  • M
  • N
  • O
  • P
  • Q
  • R
  • S
  • T
  • U
  • V
  • W
  • X
  • Y
  • Z
Temperature Distribution
Temperature measurement of the heating medium (e.g., forced hot air) across the chamber load zone. (TR01) (TR03) (TR30) (TR48)

Source:

Sterilization Cycle
A sequence of defined operating parameters (e.g., time, temperature and pressure) and conditions required to render an item sterile. (TR01) (TR30) (TR48) A sequence of defined operating parameters (e.g., time and temperature) required to render an item sterile. (TR3)

Source:

Risk Evaluation
The comparison of the estimated risk to given risk criteria using a quantitative or qualitative scale to determine the significance of the risk (TR30) (TR54-2) (TR44) (TR58) (TR54-5)

Source:

Risk
The combination of the probability of occurrence of harm and the severity of that harm.(TR30) (TR44) (TR54) (TR54-2) (TR54-4) (TR58) (TR67) (TR68) (TR88)

Source:

Risk Assessment
A systematic process of organizing information to support a risk decision to be made within a risk management process. It consists of identification of hazards and the analysis and evaluation of risk associated with exposure to those hazards. (TR30) (TR44) (TR54) (TR58) (TR55) (TR67) (TR57-2) (TR54-5) (TR88)

Source:

Quality System
Formalized business practices that define management responsibilities for organizational structure, processes, procedures, and resources needed to fulfill product/service requirements, customer satisfaction, and continual improvement. (TR30) (TR44) The sum of all aspects of a system that imple­ments quality policy and ensures that quality ob­jectives are met. (TR54-5)

Source:

Product-specific Design Approach
A sterilization design approach that is based on the characteristics of the bioburden (on or in the load) and the heat sensitivity of the product that delivers the lethality needed to achieve a PNSU of 10-6 on or in the items to be sterilized. (TR01) (TR3) (TR30)

Source:

Overkill Design Approach
A sterilization design approach where minimal information is required about the product bioburden. A worst-case bioburden assumption is used to determine the delivered lethality needed to achieve a PNSU of 10-6 on or in the items being sterilized. When using this approach, the qualification program must demonstrate that both the FBIO and FPHYS are greater than 12 minutes. The required lethality may vary regionally. (Note: For typical SIP systems, the FPHYS will need to be greater than the FBIO.) (TR01) (TR3) (TR30) (TR61)

Source:

Performance Attribute
An output variable or outcome that cannot be directly controlled but is a measurable indicator that the process performed as expected (e.g., bioburden, load monitor). [Synonym: performance parameter] (TR30)

Source:

Parametric Release
A sterility release system based upon effective control, monitoring, documentation, and batch records review of a validated sterilization process cycle in lieu of release procedures based upon end-product sterility testing. (TR01) (TR3) (TR13) A sterility release program based on effective control, monitoring and documentation of a validated sterile-product manufacturing process where sterility release is based on demonstrated achievement of critical operational parameters and performance attributes in lieu of end-product sterility testing. (TR30)

Source:

Liquid Load
A load consisting of closed containers of aqueous liquids. The sterilization of the container contents is achieved through transfer of energy through the container into the aqueous liquid. (TR01) (TR30) (TR48)

Source:

Load Monitor
A chemical, physical or biological indicator that provides an indication that a load was exposed to moist heat processing conditions. Note: In the United States, the load monitor must consist of a device in the form of a chemical, physical or biological indicator that is capable of direct measurement, or if appropriate, an indirect measurement of physical lethality delivered to the load. (TR30)

Source:

Maximum Load
The maximum quantity or mass of items permitted in a sterilizer load. (TR01) The maximum quantity or mass of items permitted in a depyrogenation or sterilization load. (TR3) The maximum quantity or mass of products permitted in a validated sterilizer load. (TR30)The maximum quantity or mass of items permitted in a sterilizer load. (TR48)

Source:

F-Value (Lethality Factor)
A measurement of sterilization effectiveness, the F-value is the calculated equivalent lethality (using a specified z-value), in terms of minutes at a reference temperature (Tref), delivered by a sterilization cycle. (TR1) (TR3) (TR30) (TR48) (TR61)

Source:

Design Space
The multidimensional combination and interaction of input variables (e.g., material attributes) and operational parameters that have been demonstrated demonstrated to provide assurance of quality. Working within the design space is not considered as a change. Movement out of the design space is considered to be a change and would normally initiate a regulatory post approval change process. Design space is proposed by the applicant and is subject to regulatory assessment and approval. (TR30) (TR60) (TR 57-2)

Source:

Chemical Integrator
A device that is designed to react in a quantitative manner to multiple sterilization variables, (typically, time and temperature and, in some instances, moisture). (TR01) (TR30)

Source:

Chemical Indicator
Test system that reveals change in one or more predefined process variables based on a chemical or physical change resulting from exposure to a process. (TR01) (TR30)

Source:

Biological Qualification
A component of performance qualification that demonstrates, by use of biological indicators, that the required lethality (FBIO) is achieved consistently throughout the load. (TR1) (TR3) (TR30) A component of performance qualification that demonstrates, by use of biological indicators, that the required lethality (FBIO) or spore log reduction (SLR) is achieved consistently throughout the sterilized or sanitized portion of the SIP system. (TR61)

Source: