Nondestructive
A method in which a passing sample can subsequently be utilized in additional analytical methods or processed to a final product. (TR86)
Source:
New Drug Application (NDA)
An application filed with the FDA used for the regulation and control of new drugs in the United States; the goal is to provide enough information to permit the FDA reviewer to reach the following key decisions: whether the drug is safe and effective in its proposed use(s), and whether the benefits of the drug outweigh the risks; whether the drugs proposed labeling (package insert) is appropriate, and what it should contain; whether the methods used in manufacturing the drug, and the controls used to maintain the drug’s quality are adequate to preserve the drug’s identity, strength, quality, and purity. (TR56)
Source:
Nonconformity (ISO def.)
A condition of any product or component in which one or more characteristics do not conform to requirements. Includes failures, deficiencies, defects, and malfunctions. [Synonym: Defect](TR43)(TR76)
Source:
Nominal Value
The assumed activity of an endotoxin preparation, dilution, or "spike"; based on label-claim information.(TR82)
Source:
Naturally Occurring Endotoxin (NOE)
Endotoxin prepared from Gram-negative bacteria produced under defined conditions and with minimal nonchemical processing, e.g., centrifugation and filtration.(TR82)
Source:
Non-fiber Releasing
Refers to a filter that does not shed fibers into the filtrate. (TR26)
Source:
Nucleic Acid Amplification Technique (NAT)
A method for detection, and in some cases, quantification of target organisms via detection of organism specific nucleic acid. PCR or polymerase chain reaction is a common NAT method that is based on amplification of targeted sequences using primers and specialized DNA polymerases. (TR50)
Source:
Nonfiber Releasing Filter
Nonfiber-releasing filter means any filter, which after any appropriate pretreatment, such as washing or flushing, will not release fibers into the component or drug product that is being filtered. All filters composed of asbestos are deemed to be fiber-releasing filters. (TR45)
Source:
Nonviable
A term used in reference to particulates that are not capable of living, growing, or developing and functioning successfully (“unable to divide” or “not capable of reproducing”). (TR13)
Source:
Nest (Tub Nest)
Rigid plastic support placed into a tub to keep syringes upright with sufficient separation to allow for easy manipulation by manual or automated fill-line systems. (TR73)
Source:
Nonclinical Laboratory Study
For this report, nonclinical laboratory study means in vivo or in vitro experiments, in which test articles are studied prospectively in test systems under laboratory conditions in order to determine their safety. The definition does not include: studies using human subjects or clinical studies, field trials in animals, or any basic exploratory studies carried out to determine whether a test article has any potential utility or to determine physical or chemical characteristics as described in ICH S6 and 21 CFR Part 58 (GLP).
Note: Also referred to as Preclinical, Toxicity or “Tox” studies. (TR56)
Source:
Non-Condensable Gases
Air and other gases that will not condense to liquid state, thereby not releasing latent heat under the conditions of sterilization. (TR01)
Source:
Needle-Safety Device
A safety feature or mechanism that effectively reduces the risk of an exposure incident (e.g., accidental needlestick). (TR73)
Source:
Normal Dose
The therapeutic dose of a product as given on the approved product labeling. (TR29) (TR49)
Source:
Nosocomial Infection (hospital-related infection)
An infection acquired in a hospital or other healthcare institution that was not present at the time of admission; the most common sites of infection are the urinary tract, surgical wound and lower respiratory tract and bloodstream. The vast majority of nosocomial infections are associated with use of invasive medical devices (e.g., urinary tract catheters, ventilators and central venous catheters). (TR67)
Source:
Nuclease
An enzyme capable of cleaving the phosphodiester bonds between the nucleotide subunits of nucleic acids. (TR47)
Source:
Needle Shield (Needle Cover)
Rigid or flexible polymeric substance used to seal and protect the needle. (TR73)
Source:
Nonspecific Model Virus
A virus used for characterization of viral clearance of the process when the purpose is to characterize the capacity of the manufacturing process to remove and/or inactivate viruses in general (i.e., to characterize the general viral clearance capacity of the purification process.) (TR41)
Source:
Nominal Molecular-Weight Cutoff (NMWCO)
A manufacturer’s measure of an ultrafiltration membrane based on a defined solute-retention coefficient. (TR15)
Source:
Needle (Cannula)
A thin, hollow, metal tube commonly used with a syringe to inject substances into the body. (TR73)
Source:
Nucleic Acid Sequence Based Amplification (NASBA)
An isothermal amplification method targeting RNA in which amplifications of RNA occurs via DNA intermediates. Each of the DNA templates can make 100 to 1000 copies of RNA amplicons, potentially resulting in the production of greater than a billion amplicons. (TR50)
Source:
Noninferiority
A comparison with the primary objective of showing that the result from one method is not inferior to the method being compared. This is usually demonstrated by showing that the true difference is likely to lie above the lower equivalence margin. (TR57)
Source:
Nonconformity Classifications
Critical: A Nonconformity that is likely to result in personal injury or potential hazard to the patient. This classification includes any nonconformity that compromises the integrity of the container, and risks microbiological contamination of a sterile product.
Major A: A Nonconformity leading to serious impairments, for example, a malfunction that makes the packaging unusable.
Major B: A Nonconformity leading to impairments of a lesser degree, for example, reduced efficiency in production.
Minor: A Nonconformity that does not impact product quality or process capability.
N/A: An imperfection classification that is less than the size, magnitude and impact of a nonconformity is considered not applicable. Therefore an imperfection that is considered to be non-applicable is acceptable.(TR43)
Critical: A nonconformity that risks personal injury or potential hazard to the patient. Any nonconformity that risks container closure in¬tegrity is assigned to this classification.
Major A: A nonconformity leading to serious container impairments, e.g., a malfunction making packaging unusable.
Major B: A nonconformity leading to contain¬er impairments of a lesser degree, e.g., reduced efficiency in production.
Minor: A nonconformity that does not impact product quality or process capability.
N/A: Imperfections that are considered to be nonapplicable or nondefects and are therefore acceptable.(TR 76)
Source:
Nucleic Acid Standard
A sample with a precisely measured content of specific nucleic acid. A nucleic acid standard can be serially diluted to assess the limit of detection of an NAT assay or to create a standard curve for Q-PCR to determine the concentration of target nucleic acid. (TR50)
Source:
Normal Operating Range (NOR)
A defined range, within (or equal to) the Proven Acceptable Range, specified in the manufacturing instructions as the target and range at which a process parameter is controlled, while producing unit operation material or final product meeting release criteria and CQAs. (TR60) (TR60-2)
Source:
Nominal Pore Size Rating
A filter rating with an arbitrary value, indicating a particulate size range at which the filter manufacturer claims the filter removes some percentage. Nominal ratings vary from manufacturer to manufacturer and may not be suitable to compare filters among manufacturers. Processing conditions, such as operating pressure and concentration of contaminant may have a significant effect on the retention efficiency of the nominally rated filters. (TR41)
Source:
Negative Control
A test article used to assess the performance of an assay in the known absence of a targeted microorganism or nucleic acid. Negative controls are used to minimize a risk of false positive results, which could occur due to non-specific signals. (TR50)
Source:
Nonconformity (ANSI def.)
A departure of a quality characteristic from its intended level or state that occurs with severity sufficient to cause an associated product or service not to meet a specification requirement. [Synonym: Defect] (TR43)(TR76)
Source: