PDA Technical Glossary
PDA Technical Reports are highly valued membership benefits because they offer expert guidance and opinions on important scientific and regulatory topics and are used as essential references by industry and regulatory authorities around the world. These reports include terms which explain the material and enhance the reader’s understanding.
The database presented here includes the glossary terms from all current technical reports. The database is searchable by keyword, topic, or by technical report. Each definition provided includes a link to the source technical report within the PDA Technical Report Portal.
(Please select "All" to restart a filtered Search)
Refine Results
Filter By Technical Report Number
- TR 13: Environmental Monitoring (4)
- TR 51: Biological Indicators (2)
- TR 61: Steam in Place (2)
- TR 62: Manual Aseptic Processes (2)
- TR 70: Cleaning/Disinfection Programs (2)
- TR 45: Depth Filtration (2)
- TR 47: Virus Spikes/Virus Clearance (1)
- TR 67: Objectionable Microorganisms (1)
- TR 14: Validation: Protein Purification Chromatography (1)
- TR 22: Aseptic Process Simulation (1)
- TR 26: Sterilizing Filtration of Liquids (1)
- TR 28: Process Simulation for Bulk API (1)
- TR 43: Glass Defects (1)
Filter By Technical Report Keyword
Filter By Technical Report Category
Aseptic Processing
Handling sterile materials in a controlled environment, in which the air supply, facility, materials, equipment and personnel are regulated to control microbial and particulate contamination to acceptable levels. (TR28) (TR62) (TR69) Handling of sterile product, containers, and/ or devices in a controlled environment in which the air supply, materials, equipment, and personnel are regulated to maintain (product) sterility. (TR13)
Source:
Bioburden
The total number of microorganisms per unit of material prior to sterilization. (TR13) Total number of viable microorganisms on or in a health care product prior to sterilization. (TR22)(TR61)(TR62) A population of viable microorganisms in a fluid prior to sterilizing filtration. (TR26) A measure of the contaminating organisms found in or on a given amount of material before it undergoes a sterilization process. (TR45) (TR70) The number of detectable microorganisms (bacteria and fungi) with which an object is contaminated. It is measured in CFU (colony forming units). (TR47) The number of viable, contaminating microorganisms present on a product immediately prior to decontamination. (TR51) Viable microbial contaminants associated with personnel manufacturing environments (air and surfaces), equipment, product packaging, raw materials (including water), in-process materials, and finished products. (TR 67) (TR 69)
Source:
Biofouling (or Biological Fouling)
Accumulation and subsequent deleterious effects of biological contaminants on engineered products or processes (TR 69)
Source:
Dead Leg
Area of entrapment in a vessel or piping run that could lead to contamination of the product. (TR69)
Source:
Disinfection
The destruction of pathogenic and other kinds of microorganisms by thermal or chemical means. (TR51) (TR70) Process of eliminating nearly all recognized pathogenic microorganisms but not necessarily all microbial forms (e.g., bacterial spores) on inanimate objects. (TR69) The chemical or physical inactivation of a bioburden on inanimate surfaces. Typically this requires a minimum three-log (3-log) reduction of vegetative microorganisms and two-log (2-log) reduction for bacterial spore be achieved in validation. (TR13)
Source:
Sanitization
Reduction of microbial contaminants to safe levels as judged by public health requirements for the specific country. (TR13) A significant reduction in bioburden, achieved in chromatography by the use of bactericidal agents, such as sodium hydroxide (NaOH), hydrochloric acid (HCl), ethanol (EtOH), and isopropanol (IPA). (TR14) The process of reducing microbial levels by treatment at less than defined sterilizing conditions. Typically water at 80 °C or a chemical treatment is used to perform sanitization of process components. (TR45) A process that reduces the number of viable microorganisms to a defined level. (TR61) (TR69)