PDA Technical Reports are highly valued membership benefits because they offer expert guidance and opinions on important scientific and regulatory topics and are used as essential references by industry and regulatory authorities around the world. These reports include terms which explain the material and enhance the reader’s understanding.

The database presented here includes the glossary terms from all current technical reports. The database is searchable by keyword, topic, or by technical report. Each definition provided includes a link to the source technical report within the  PDA Technical Report Portal.

(Please select "All" to restart a filtered Search)

Refine Results
Filter By Technical Report Number
Filter By Technical Report Keyword
Filter By Technical Report Category
    Displaying results 1 - 50 of 165
  • 1
  • 2
  • 3
  • 4
  • »
Acceptance Criteria
Numerical limits, ranges, or other suitable measures for acceptance of test results. (TR 14) (TR 29) (TR 38) (TR 64) Numerical limits, ranges, or other suitable measures for acceptance of test results. Exceeding the acceptable range for a critical parameter during subsequent validation studies may result in questionable product quality that would require initiation of an investigation. Exceeding the operating range should be documented and explained in the validation report and evaluated for validation study impact. (TR 42) The pre-defined specifications, standards or ranges that must be met under stated test conditions. (TR 48) Numerical limits, ranges, or other suitable measures for acceptance of the results of analytical method validation that is satisfied to determine suitability of test method performance.(TR 57) (TR 69) (TR 72) (TR 74) The criteria that a system or component must satisfy in order to be accepted by a user or other authorized entity. (TR 54-5) Numerical limits, ranges, or other suitable measures for acceptance of the results of analytical procedures which the drug substance or drug product or materials at other stages of their manufacture should meet (16). Exceeding the acceptable range for a critical parameter during subsequent validation studies may result in questionable product quality that would require initiation of an investigation and possible batch rejection. (TR60)
Source:
Acceptance Limit
The maximum amount of residue allowed in a product, in an analytical sample, or as an amount per surface area. (TR29)
Source:
Accuracy
The closeness of the actual test results obtained by the new method to the actual test results obtained by the existing method. (TR33) An analytical procedure expresses the closeness of agreement between the value that is accepted either as a conventional true value or an accepted reference value and the value found. This is sometimes termed trueness. (TR57)
Source:
Air Removal Test
A test used to evaluate air removal and steam penetration in an empty sterilizer that is used for porous/hard goods load sterilization (e.g., Bowie-Dick Test, DART, Lantor Cube, Browns’ Test). (TR01) (TR 48)
Source:
Airlock
Amplicon
A segment of double stranded DNA formed as the product of polymerase chain reaction or other amplification based techniques such as TMA or NASBA. (TR50)
Source:
Anaerobe
Analysis of Variance (ANOVA)
A general statistical approach to data analysis (i.e., comparison of means) in which the variation in a method’s results is partitioned among explanatory factors in order to systematically assess factor influence and/or variance components. (TR57)
Source:
Analyte
Substance (usually a residue) for which an analysis is being performed. (TR29) (TR49) (TR70) A specific chemical moiety being measured, which can be intact drug, biomolecule or its derivative, impurity, and/or excipients in a drug product. [Synonym: measurand] (TR57)
Source:
Analytical Control
Material used to monitor the performance of a method to assess the integrity and validity of the results. (TR57-2)
Source:
Analytical Instrument Qualification (AIQ)
The qualification of the analytical instrument(s) used as part of the analytical procedure. (TR57)
Source:
Analytical Method Comparability (AMC)
Equivalence study that measure the same property of two methods and that shows that replacing one of these methods with the other would not adversely affect the test’s use or results. (TR57-2)
Source:
Analytical Method Design
Collection of activities performed to define the intended purpose of the method, select the appropriate technology to implement the method, and identify the critical method variables that need to be controlled to ensure that the method is robust and rugged. (TR57-2)
Source:
Analytical Method Development (AMD)
Collection of activities performed to select an appropriate technique and method conditions to meet the Analytical Target Profile (ATP) requirements. (TR57-2)
Source:
Analytical Method Transfer (AMT)
Documented process that qualifies a laboratory (receiving unit) to use an analytical test procedure that originates in another laboratory (the transferring unit, also known as the sending unit), thus ensuring that the receiving unit has the knowledge and ability to perform the transferred analytical procedure as intended. (TR57-2)
Source:
Analytical Platform Technology (APT)
An analytical method that is used for multiple products and/or types of sample matrix without modification of the procedure. Similar to compendial methods, an APT method may not require full validation for each new product or sample type. (TR57)
Source:
Analytical Procedure
That which is performed in order to obtain a reportable result. The procedure should describe in detail the steps necessary to perform the analytical test. This may include but is not limited to: the sample, the reference standard and the reagents preparations, use of the apparatus, generations of the calibration curve, use of the formulae for the calculation [Synonym: Method, Assay] (TR57)
Source:
Antimicrobial Chemical Agent
Substance used to destroy or suppress the growth of microorganisms, whether bacteria, fungi, or viruses, on inanimate objects and surfaces. (TR70)
Source:
Area Disinfection
Aseptic Processing
Handling sterile materials in a controlled environment, in which the air supply, facility, materials, equipment and personnel are regulated to control microbial and particulate contamination to acceptable levels. (TR28) (TR62) (TR69) Handling of sterile product, containers, and/ or devices in a controlled environment in which the air supply, materials, equipment, and personnel are regulated to maintain (product) sterility. (TR13)
Source:
Aseptic Processing Area (APA)
Controlled environment, consisting of several zones, in which the air supply, facility, materials, equipment and personnel are regulated to control microbial and particulate contamination to acceptable levels. (TR22) (TR28) (TR62) (TR70)
Source:
Aseptic Processing Simulation (APS)
Bias
A systematic difference in a method that manifests itself as a deviation of the method mean from an expected value. (TR57) Total systematic error, in contrast to random error. Measurement centered on the true result is said to be unbiased or have no systematic error. The distance between the center of a large (infinite) number of measurements and the correct value is the bias. (TR 57-2)
Source:
Bioanalytical Test Method
A method used to assess the presence of analytes (chemical or biological) in biological samples (e.g., serum, plasma, etc.). (TR57)
Source:
Bioassay
Analysis (as of a drug) to quantify the biological activity(ies) of one or more components by determining its capacity for producing an expected biological activity. (TR57)
Source:
Bioburden
The total number of microorganisms per unit of material prior to sterilization. (TR13) Total number of viable microorganisms on or in a health care product prior to sterilization. (TR22)(TR61)(TR62) A population of viable microorganisms in a fluid prior to sterilizing filtration. (TR26) A measure of the contaminating organisms found in or on a given amount of material before it undergoes a sterilization process. (TR45) (TR70) The number of detectable microorganisms (bacteria and fungi) with which an object is contaminated. It is measured in CFU (colony forming units). (TR47) The number of viable, contaminating microorganisms present on a product immediately prior to decontamination. (TR51) Viable microbial contaminants associated with personnel manufacturing environments (air and surfaces), equipment, product packaging, raw materials (including water), in-process materials, and finished products. (TR 67) (TR 69)
Source:
Biofouling (or Biological Fouling)
Accumulation and subsequent deleterious effects of biological contaminants on engineered products or processes (TR 69)
Source:
Biological Activity
Property that describes the specific ability or capacity of a product to achieve a defined biological effect. (TR57)
Source:
Biological Indicator (BI)
An inoculated carrier contained within its primary pack ready for use and providing a defined resistance to the specified sterilization process. (TR51)
Source:
Biological Qualification
A component of performance qualification that demonstrates, by use of biological indicators, that the required lethality (FBIO) is achieved consistently throughout the load. (TR1) (TR3) (TR30) A component of performance qualification that demonstrates, by use of biological indicators, that the required lethality (FBIO) or spore log reduction (SLR) is achieved consistently throughout the sterilized or sanitized portion of the SIP system. (TR61)
Source:
Biological Safety Cabinet (BSC)
An enclosed, ventilated workspace with engineering controls designed to remove or minimize exposure to hazardous biological materials. A BSC is a principle device to provide containment of infectious splashes or aerosols generated by many microbiological procedures. BSCs are designed to provide personnel, environmental and product protection when appropriate practices and procedures are followed. A cabinet that is designed to protect the operator and the environment from the hazards of handling infected material and other dangerous biological. (TR62)
Source:
Biological Tests
Biological tests include animal, cell culture, or biochemical based testing that measures a biological, biochemical, or physiological response. (TR38)
Source:
Carrier
A solid support upon which the test organism used in biological monitoring is inoculated. (TR51)
Source:
Characterization Study
A series of tests designed to increase process knowledge by examining proposed operational ranges and their individual and/or combined impact on the chromatography process. (TR14) A late-stage study that evaluates the process to increase process knowledge and examines proposed operational ranges and their individual and/or combined impact on target protein quality. (TR42)
Source:
Contact Time
The minimum amount of time that a sanitizer, disinfectant, or sporicide must be left in complete (wet) contact with the surface to be treated in order to be effective. (TR70)
Source:
Contaminants (Contamination)
Any adventitiously introduced materials (e.g., chemical, biochemical, or microbial species) not intended to be part of the manufacturing process of the drug substance or drug product (16). The undesired introduction of impurities of a chemical or microbiological nature, or of foreign matter, into or onto a raw material, intermediate, or API [drug substance] during production [manufacture], sampling, packaging or repackaging, storage or transport (17).
Source:
Correlation Coefficient ( r )
A measure of covariation, the square root of the coefficient of determination. (TR57)
Source:
Coupon
A small, generally flat portion of a defined material of construction (such as stainless steel or PTFE) and of a defined surface finish, typically used for laboratory cleaning evaluations and/or for laboratory sampling recovery studies. (TR29) (TR49)
Source:
Coverage
The appropriate distribution of a chemical agent needed on the equipment surface to be effective. (TR70)
Source:
Critical Process (CP)
A process that impacts a critical quality attribute of the intermediate, drug substance or drug product being manufactured and therefore should have established critical process parameters that can be monitored or controlled to ensure that the process produces the desired quality.
Source:
Cycle Development
A series of activities performed for the purpose of defining or confirming the cycle parameters (e.g., time, temperature, pressure) necessary to ensure sanitization or sterilization. (TR61)
Source:
Cycle Phases
A discrete series of sterilizer process steps (such as, heat-up, exposure and cool-down) performed sequentially that represent a complete sterilization cycle. (TR48)
Source:
Cytopathic Effect (CPe)
Morphological changes induced by viruses in infected cells in invitro culture. They are usually localized around a site of initial infection and vary in appearance based on the virus and the cultured cell. (TR47)
Source:
Cytopathic Virus
Viruses where infection of cells results in microscopically visible degeneration of the cells or other morphological changes. (TR47)
Source:
D-Value
The time in minutes required for a one-logarithm, or 90%, reduction of the population of microorganisms used as a biological indicator under specified lethal conditions. For dry-heat sterilization, the D-value should always be specified with a reference temperature, DT. For example, a biological indicator (BI) challenge system with a D 160°C=1.9 minutes, requires 1.9 minutes at 160°C to reduce the population by one logarithm. (TR3) The time in minutes at a specific temperature required to reduce the population of a specific microorganism by 90% [or one (1) log] in defined conditions [e.g., method of sterilization (dry heat versus steam), solute, or carrier]. (TR13)
Source:
D-value (D10 -Value)
The time in minutes required for a one-logarithm, or 90%, reduction of the population of microorganisms used as a biological indicator under specified lethal conditions. (TR51)
Source:
DT Value
The time in minutes required for a onelogarithm, or 90%, reduction of the population of microorganisms used as a biological indicator under specified lethal conditions. For steam sterilization, the D-value should always be specified with a reference temperature, DT . For example, a BI system with a D121°C = 1.4 minutes requires 1.4 minutes at 121°C to reduce the population by one logarithm.(TR1) (TR61)
Source:
Darcy Permeability
The constant of proportionality of the material as defined by Darcy’s Law. (TR45)
Source:
Dead Leg
Area of entrapment in a vessel or piping run that could lead to contamination of the product. (TR69)
Source:
Deadlegs
An area of entrapment in the vessel or piping run that could lead to contamination of the product due to insufficient exposure to moist heat. (TR61)
Source: