PDA Technical Glossary
PDA Technical Reports are highly valued membership benefits because they offer expert guidance and opinions on important scientific and regulatory topics and are used as essential references by industry and regulatory authorities around the world. These reports include terms which explain the material and enhance the reader’s understanding.
The database presented here includes the glossary terms from all current technical reports. The database is searchable by keyword, topic, or by technical report. Each definition provided includes a link to the source technical report within the PDA Technical Report Portal.
(Please select "All" to restart a filtered Search)
Refine Results
Filter By Technical Report Number
- TR 69: Bioburden/Biofilm Management (3)
- TR 51: Biological Indicators (2)
- TR 61: Steam in Place (2)
- TR 70: Cleaning/Disinfection Programs (2)
- TR 3: Validation: Dry Heat (2)
- TR 45: Depth Filtration (2)
- TR 47: Virus Spikes/Virus Clearance (1)
- TR 62: Manual Aseptic Processes (1)
- TR 67: Objectionable Microorganisms (1)
- TR 1: Validation: Moist Heat (1)
- TR 14: Validation: Protein Purification Chromatography (1)
- TR 22: Aseptic Process Simulation (1)
- TR 26: Sterilizing Filtration of Liquids (1)
- TR 30: Parametric Release (1)
- TR 43: Glass Defects (1)
Filter By Technical Report Keyword
Filter By Technical Report Category
Bioburden
The total number of microorganisms per unit of material prior to sterilization. (TR13) Total number of viable microorganisms on or in a health care product prior to sterilization. (TR22)(TR61)(TR62) A population of viable microorganisms in a fluid prior to sterilizing filtration. (TR26) A measure of the contaminating organisms found in or on a given amount of material before it undergoes a sterilization process. (TR45) (TR70) The number of detectable microorganisms (bacteria and fungi) with which an object is contaminated. It is measured in CFU (colony forming units). (TR47) The number of viable, contaminating microorganisms present on a product immediately prior to decontamination. (TR51) Viable microbial contaminants associated with personnel manufacturing environments (air and surfaces), equipment, product packaging, raw materials (including water), in-process materials, and finished products. (TR 67) (TR 69)
Source:
D-Value
The time in minutes required for a one-logarithm, or 90%, reduction of the population of microorganisms used as a biological indicator under specified lethal conditions. For dry-heat sterilization, the D-value should always be specified with a reference temperature, DT. For example, a biological indicator (BI) challenge system with a D 160°C=1.9 minutes, requires 1.9 minutes at 160°C to reduce the population by one logarithm. (TR3) The time in minutes at a specific temperature required to reduce the population of a specific microorganism by 90% [or one (1) log] in defined conditions [e.g., method of sterilization (dry heat versus steam), solute, or carrier]. (TR13)
Source:
Disinfection
The destruction of pathogenic and other kinds of microorganisms by thermal or chemical means. (TR51) (TR70) Process of eliminating nearly all recognized pathogenic microorganisms but not necessarily all microbial forms (e.g., bacterial spores) on inanimate objects. (TR69) The chemical or physical inactivation of a bioburden on inanimate surfaces. Typically this requires a minimum three-log (3-log) reduction of vegetative microorganisms and two-log (2-log) reduction for bacterial spore be achieved in validation. (TR13)
Source:
Parametric Release
A sterility release system based upon effective control, monitoring, documentation, and batch records review of a validated sterilization process cycle in lieu of release procedures based upon end-product sterility testing. (TR01) (TR3) (TR13) A sterility release program based on effective control, monitoring and documentation of a validated sterile-product manufacturing process where sterility release is based on demonstrated achievement of critical operational parameters and performance attributes in lieu of end-product sterility testing. (TR30)
Source:
Sanitization
Reduction of microbial contaminants to safe levels as judged by public health requirements for the specific country. (TR13) A significant reduction in bioburden, achieved in chromatography by the use of bactericidal agents, such as sodium hydroxide (NaOH), hydrochloric acid (HCl), ethanol (EtOH), and isopropanol (IPA). (TR14) The process of reducing microbial levels by treatment at less than defined sterilizing conditions. Typically water at 80 °C or a chemical treatment is used to perform sanitization of process components. (TR45) A process that reduces the number of viable microorganisms to a defined level. (TR61) (TR69)