PDA Technical Reports are highly valued membership benefits because they offer expert guidance and opinions on important scientific and regulatory topics and are used as essential references by industry and regulatory authorities around the world. These reports include terms which explain the material and enhance the reader’s understanding.

The database presented here includes the glossary terms from all current technical reports. The database is searchable by keyword, topic, or by technical report. Each definition provided includes a link to the source technical report within the  PDA Technical Report Portal.

(Please select "All" to restart a filtered Search)

  • All
  • 0
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • A
  • B
  • C
  • D
  • E
  • F
  • G
  • H
  • I
  • J
  • K
  • L
  • M
  • N
  • O
  • P
  • Q
  • R
  • S
  • T
  • U
  • V
  • W
  • X
  • Y
  • Z
Acceptance Criteria
Numerical limits, ranges, or other suitable measures for acceptance of test results. (TR 14) (TR 29) (TR 38) (TR 64) Numerical limits, ranges, or other suitable measures for acceptance of test results. Exceeding the acceptable range for a critical parameter during subsequent validation studies may result in questionable product quality that would require initiation of an investigation. Exceeding the operating range should be documented and explained in the validation report and evaluated for validation study impact. (TR 42) The pre-defined specifications, standards or ranges that must be met under stated test conditions. (TR 48) Numerical limits, ranges, or other suitable measures for acceptance of the results of analytical method validation that is satisfied to determine suitability of test method performance.(TR 57) (TR 69) (TR 72) (TR 74) The criteria that a system or component must satisfy in order to be accepted by a user or other authorized entity. (TR 54-5) Numerical limits, ranges, or other suitable measures for acceptance of the results of analytical procedures which the drug substance or drug product or materials at other stages of their manufacture should meet (16). Exceeding the acceptable range for a critical parameter during subsequent validation studies may result in questionable product quality that would require initiation of an investigation and possible batch rejection. (TR60)
Source:
Critical Aspect Design Elements (CADE)
Critical aspect design elements are components, instruments, and process controls that comprise the critical aspect (e.g., temperature feedback loop). Critical aspect design elements are tested in commissioning and qualification. (TR54-5)
Source:
Critical Aspects (CAs) of Manufacturing Systems
Critical aspects are constituent parts of a system or piece of equipment that provide the ability to control one or more critical process parameter of the associated process (e.g., temperature control­ler of a bioreactor). (TR54-5)
Source:
Design Reviews
Planned and systematic reviews of specifications, design, and design development and continuous improvement changes performed as appropriate throughout the lifecycle of the manufacturing sys­tem. Design reviews evaluate deliverables against standards and requirements, identify problems, and propose required corrective actions. (TR54-5)
Source:
Design Specification
Controlled documentation that clearly and explic­itly defines the manufacturing system details, codes, and standards to be followed during fabrication and construction to meet associated requirements. (TR54-5)
Source:
Preliminary/Process Hazard Analysis (PHA)
A tool of analysis based on applying prior experience or knowledge of a hazard or failure to identify future hazards, hazardous situations and events that might cause harm, as well as to estimate their probability of occurrence for a given activity, facility, product or system. (TR54-5)
Source: