PDA Technical Glossary

PDA Technical Glossary

PDA Technical Reports are highly valued membership benefits because they offer expert guidance and opinions on important scientific and regulatory topics and are used as essential references by industry and regulatory authorities around the world. These reports include terms which explain the material and enhance the reader’s understanding.

The database presented here includes the glossary terms from all current technical reports. The database is searchable by keyword, topic, or by technical report. Each definition provided includes a link to the source technical report within the  PDA Technical Report Portal.

(Please select "All" to restart a filtered Search)

Refine Results
Filter By Technical Report Number
Filter By Technical Report Keyword
Filter By Technical Report Category
    Displaying results 1 - 50 of 74
  • 1
  • 2
  • »
Amplicon
A segment of double stranded DNA formed as the product of polymerase chain reaction or other amplification based techniques such as TMA or NASBA. (TR50)
Source:
Anaerobe
Anaerobic Microorganism
A microorganism that does not utilize oxygen as the final electron acceptor during metabolism; microorganism that will grow only in the absence of oxygen. (TR62)(TR22)
Source:
Aseptic Processing Simulation (APS)
Assess the Effects of the Change
To evaluate the effects of a manufacturing change on the identity, strength, quality, purity, and potency of a drug product as those factors may relate to the safety or effectiveness of the drug product. (TR38)
Source:
Attribute
A physical, chemical, or microbiological property or characteristic of an input or output material. (TR60)
Source:
Attribute Sampling
Inspection where either the unit of product is classified as conforming or non-conforming or the number of non-conformities in the unit of products is counted with respect to a given requirement of set of requirements. (TR43)
Source:
Attributes (Process Performance Attribute)
An output variable or outcome that cannot be directly controlled, but is an indicator that the process performed as expected.(Synonym - Process Performance Parameter) (TR60)
Source:
Attributes (Quality Attribute)
A molecular or product characteristic that is selected for its ability to indicate the quality of the product. Collectively, the quality attributes define identity, purity, potency and stability of the product, and safety with respect to adventitious agents. Specifications measure a selected subset of the quality attributes. (TR60)
Source:
Chamber Leak Test
A test conducted to evaluate possible air infiltration to the chamber under vacuum. [Synonym: Vacuum Leak Test] (TR1) (TR48)
Source:
Change Control
A formal program that describes evaluation and actions to be taken if a change is proposed or completed to facilities, materials, equipment, and/or processes used in the fabrication, packaging, and testing of drugs, or a proposed or completed change that may affect the operation of the quality or support systems. (TR22) (TR39) (TR52) (TR58) (TR64) (TR 70)
Source:
Class I Recall
A situation in which there is a reasonable probability that the use of or exposure to a violative product will cause serious adverse health consequences or death. (TR55)
Source:
Class II Recall
A situation in which use of or exposure to a violative product or may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequence is remote.(TR55)
Source:
Clinical Protocol
A document, together with any amendments to it, that describes the objectives, design, methodology, statistical considerations, and organization of a clinical trial. (TR63)
Source:
Clinical Trial Material (CTM)
A drug or combination of drugs and/or excipients that are produced with the intent that it be used in a clinical trial, or that is released or otherwise authorized for use in such. This could, subject to appropriate regulatory approval, be an experimental medicine, a product with marketing authorization used in a clinical trial within or beyond the approved indication and/or any placebo articles produced for use in a clinical trial. (TR63)
Source:
Clinician
A physician, psychiatrist, etc., who specializes in clinical work as opposed to one engaged in laboratory or experimental studies. (TR58)
Source:
Cold Chain Tolerance Groups
This concept expands the “normal” definition of cold chain to include all products that need to be stored below 250C and also introduces the ancillary terms “ambient temperatures” and “controlled ambient”. (TR46)
Source:
Commissioning
A well planned, documented and managed engineering approach to the start-up and transfer of facilities, systems and equipment to the end-user that results in a safe and functional environment that meets established design and user requirement specifications. Commissioning precedes Qualification and includes three phases: 1. Inspection, testing, and regulation 2. Adjustment and setting of work 3. Functional testing (TR 3) A prescribed number of activities designed to take equipment and systems from a static, substantially complete state to an operable state. (TR 48) A well planned, documented, managed engineering approach to the start-up and turnover of facilities, systems, and equipment to the end-user, that results in a safe and functional environment that meets established design requirements and stakeholder expectations.(TR 54) (TR 54-5)
Source:
Comparability Protocol
A protocol submitted by an applicant under CFR 601.12(e) and 314.70 (g) that describes the specific tests and validation studies and acceptable limits to be achieved to demonstrate the lack of adverse effect for specified types of manufacturing changes on the identity, strength, quality, purity, and potency of the product as they may relate to the safety or effectiveness of the product. Any such protocols, or change to a protocol, shall be submitted as a supplement requiring approval from FDA prior to distribution of the product. The supplement, if approved, may justify a reduced reporting category for the particular change because the use of the protocol for that type of change reduces the potential risk of an adverse effect. (TR38)
Source:
Comparability Study
An assessment of the similarities between the critical parameters and output results of two or more separate processes or methods. (TR50)
Source:
Comparative Transfer
Transfer of a method that involves the analysis of a predetermined number of samples of the same lot by both the sending and the receiving unit. (TR 57-2)
Source:
Compatibility
Proof that no adverse interaction between the filter and the process fluid has occurred. (TR26) A term used in relation to the non-reactivity of filter materials with the substance to be filtered. (TR45)
Source:
Compatibility (Filter)
The ability of a filter to be used with a particular process fluid without a change in the inherent properties of the filter. (TR41)
Source:
Compendial Procedure
Complaint Files
(a) As defined by 21 CFR Part 211.198- Complaint Files. (b) A written record of each complaint shall be maintained in a file designated for drug product complaints. The file regarding such drug product complaints shall be maintained at the establishment where the drug product involved was manufactured, processed, or packed, or such file may be maintained at another facility if the written records in such files are readily available for inspection at that other facility. 1.The written record shall include the following information, where known: the name and strength of the drug product, lot number, name of complainant, nature of complaint, and reply to complainant .2.Where an investigation under 211.192 is conducted, the written record shall include the findings of the investigation and follow-up. The record or copy of the record of the investigation shall be maintained at the establishment where the investigation occurred in accordance with 211.180. (TR55)
Source:
Container Closure Integrity (CCI)
The ability of a package to prevent product loss, to block microorganism ingress, and to limit entry of detrimental gases or other substances, thus ensuring that the product meets all necessary safety and quality standards.(TR76)
Source:
Container Cold Spot
The location within a sealed liquid container that achieves the lowest process lethality (F0) during a sterilization process. (TR01)
Source:
Corked or Cork Taint
A musty-moldy off-flavor or taste imparted to the wine primarily due to the presence of 2, Combination Products 6-trichloroanisole (2, Combination Products 6-TCA) produced by the fungalo-methylation of 2, Combination Products 6-tricholorophenol (TCP) associated with corks, wooden barrels, and construction materials in wineries. (TR55)
Source:
Critical Process (CP)
A process that impacts a critical quality attribute of the intermediate, drug substance or drug product being manufactured and therefore should have established critical process parameters that can be monitored or controlled to ensure that the process produces the desired quality.
Source:
Defect
(1) A departure of a quality characteristic from its intended level or state that occurs with a severity sufficient to cause an associated product or service not to satisfy its intended normal or foreseeable usage requirements. (TR51) (2) The nonfulfillment of intended usage requirements. The departure or absence of one or more quality characteristics from intended usage requirements. (TR43)
Source:
Distribution Testing
Qualification of packaging components for physical distribution integrity like shock, vibration, and drop tests. (TR58)
Source:
Drug Shortage Prevention & Response Plan
A document that provides a structured action plan to proactively prevent drug shortages and also respond to a shortage in the event that one occurs. (TR68)
Source:
Drug Shortage Risk Register
A single source of information on risks that can result in drug shortages, associated risk levels, risk control actions with owners, status, due dates and residual risk after appropriate risk control actions have been taken. (TR68)
Source:
Elastomer
Thermoplastic material formulation (that may or may not contain rubber/natural latex) derived from elastic polymer; often used interchangeably with the term “rubber.” (TR73)
Source:
Electronic Nose
An array of electronic sensors designed to selectively identify chemicals responsible for odors. The zNose™ system is one example that is commercially available and consists of a vapor pre-concentrator, a direct-heated high-speed chromatography column, a solid-state sensor and a programmable gate array microprocessor system. (TR55)
Source:
Enabler
A tool or process which provides the means to achieve an objective (ICH Q10). (TR54)
Source:
Excipient
A component of a drug formulation that has no active pharmacologic function. Excipients are commonly used in drug formulations as modulators of pH or osmolality for parenteral administration and as stabilizers for APIs. (TR54-4) An ingredient added intentionally to the drug substance that should not have pharmacological properties in the quantity used. (TR57) Inactive pharmaceutical ingredients in a product formulation that are responsible for the product’s manufacturability and physicochemical attributes. (TR67) (TR88)
Source:
Extractable
A chemical component that is removed from a material by application of an artificial or exaggerated force (e.g., solvent, temperature, time). The term extractable is often erroneously used to describe a leachable. (TR14) (TR15) (TR26) (TR41) (TR45) Chemical substances that can be extracted from components of material process fluid contact surfaces by exertion of an exaggerated force (e.g., organic solvent, extreme elevated temperature, ionic strength, pH, contact time, etc.) Extractables may represent most but not all of the potential leachables that may be seen in process fluids. (TR66) Extractables are organic and inorganic chemical entities that can be released from a pharmaceutical packaging/delivery system, packaging component, or packaging material of construction under laboratory conditions. (TR54-4) Organic or inorganic chemical entity that is forced out of container closure system materials and components under laboratory experimental conditions. (TR73)
Source:
First Expiration, First Out (FeFo)
A method of controlling inventory to ensure that the material with the shortest remaining shelf-life is distributed first. (TR52)
Source:
Heat-Treated Wood Pallets
Two types of methods to include kiln drying versus steam heat. (TR55)
Source:
Human Factors
A science discipline that examines human psychological, social, physical, and biological characteristics to evaluate the design, operation, or use of products or systems for optimizing human performance, health, safety, and/or habitability. [Synonym: Ergonomics] (TR62)(TR80)
Source:
In-Process Observations
Incoming Inspection
A preventative program where parts or products are subjected to evaluation upon receipt.(TR43) A program where, upon receipt, parts or products are subjected to measuring, examining, testing, or gauging one or more characteristics of a product or service, and comparing the results with specified requirements in order to establish whether conformity is achieved for each characteristic.(TR 76)
Source:
Intermodal Container
A shipping container used to ship cargo through more than one of the four traditional modes of transportation (road, air, ocean, and rail). (TR64)
Source:
Intrinsic Particles
Those particles that arise from sources related to the formulation, packaging, or assembly proces­ses. In each of these cases, the particle material (e.g., glass, stainless steel, rubber, or gasket ma­terial) could be identified as a known product-contact material. (TR78) A particle that comes from within the primary process. These are qualified product contact materials and are often associated with the primary packaging components. They are unplanned but not unexpected.(TR85)
Source:
Leachable
A chemical component that migrates from a contact surface into a drug product or process fluid during storage or normal use conditions. The term leachable is often erroneously used to describe an extractable. (TR14) (TR26) Leachables are organic and inorganic chemical entities that migrate from a packaging/delivery system, packaging component, or packaging material of construction into an associated drug product under normal conditions of storage and use or during accelerated drug product stability studies. Leachables are typically a subset of extractables or are derived from extractables. (TR54-4) Chemical substances that are leached, from product-contact or non-product-contact materials, under typical process conditions and detected in final dosage. Leachables may be a subset of extractables, and can include their reaction or breakdown products. (TR66) Organic or inorganic chemical entity that migrates from pharmaceutical container closure system components into a drug product formulation. (TR73)
Source:
Method Comparability
The demonstration of analytical method comparability (AMC) for method replacements. A study to demonstrate that a modification to an existing method either improves or does not significantly change the analytical procedure’s characteristics relative to the methods’ validation and intended use. (TR57)
Source:
Moisture Content of Wood
The moisture content of wood is calculated by the following formula: Moisture content = (Mg-Mod)/Mod. Where Mg is the green mass of the wood and Mod is its oven-dry mass (the attainment of constant mass generally after drying in an oven set at 103 ± 2 °C for 24h). The equation can also be expressed as a fraction of the mass of the water and the mass of the oven-dry wood rather than a percentage. For example, 0.59 kg/kg (oven-dry basis) expresses the same moisture content as 59% (oven-dry basis). (TR55)
Source:
Odor Perception
Odors are perceived through stimulation of receptor cells and nerve endings of the trigeminal nerve in the olfactory epithelium, which lie in a small area in the upper reaches of the nasal cavity. Odors are perceived directly through the nose (orthonasal) or during gestation when volatile odorous organaohalogens reach the olfactory centers through the nasopharyneal passage (retonasal). (TR55)
Source:
Odor Threshold
The lowest concentration of a compound detectable to 50% of the people tested. (TR55)
Source:
    Displaying results 1 - 50 of 74
  • 1
  • 2
  • »