PDA Technical Glossary
PDA Technical Reports are highly valued membership benefits because they offer expert guidance and opinions on important scientific and regulatory topics and are used as essential references by industry and regulatory authorities around the world. These reports include terms which explain the material and enhance the reader’s understanding.
The database presented here includes the glossary terms from all current technical reports. The database is searchable by keyword, topic, or by technical report. Each definition provided includes a link to the source technical report within the PDA Technical Report Portal.
(Please select "All" to restart a filtered Search)
Refine Results
Filter By Technical Report Number
- TR 64: Temp Controlled Systems Qualification (4)
- TR 58: Temp Controlled Distribution (3)
- TR 60: Process Validation (3)
- TR 72: Passive Thermal Protection Systems: Qualification/Operations (2)
- TR 39: Cold Chain (2)
- TR 48: Moist Heat Sterilizer Systems (1)
- TR 50: Alt. Methods Mycoplasma Testing (1)
- TR 51: Biological Indicators (1)
- TR 57: Analytical Method Validation (1)
- TR 62: Manual Aseptic Processes (1)
- TR 70: Cleaning/Disinfection Programs (1)
- TR 1: Validation: Moist Heat (1)
- TR 22: Aseptic Process Simulation (1)
- TR 29: Validation: Cleaning (1)
- TR 76: Identification and Classification of Visible Nonconformities in Elastomeric Components and Aluminum Seals for Parenteral Packaging (1)
- TR 33: Rapid Micro Methods (1)
- TR 43: Glass Defects (1)
Filter By Technical Report Keyword
Acceptable Quality Limit (AQL)
The quality level that is the worst-tolerable process average when a continuing series of lots are submitted for acceptance sampling. (TR43) (TR 76)
Source:
Acceptance Limit
The maximum amount of residue allowed in a product, in an analytical sample, or as an amount per surface area. (TR29)
Source:
Accuracy
The closeness of the actual test results obtained by the new method to the actual test results obtained by the existing method. (TR33) An analytical procedure expresses the closeness of agreement between the value that is accepted either as a conventional true value or an accepted reference value and the value found. This is sometimes termed trueness. (TR57)
Source:
Active Systems
Systems with active temperature control (e.g., air/sea freight containers, refrigerated trucks/cars). (TR39) System with active temperature control. It makes use of electricity or fuel for the compressor to maintain temperature. Examples include refrigerated trucks, temperature-controlled ocean containers, and active ULDs. (TR58) Actively powered system that uses electricity or other fuel source to maintain a temperaturecontrolled environment inside an insulated enclosure under thermostatic regulation (e.g., cold room, refrigerator, temperature-controlled truck, refrigerated ocean or air container). (TR64) (TR72) (Synonym: Active Temperature Controlled System)
Source:
Active Temperature Controlled System
Actively powered system that uses electricity or other fuel source to maintain a temperaturecontrolled environment inside an insulated enclosure under thermostatic regulation (e.g., cold room, refrigerator, temperature-controlled truck, refrigerated ocean or air container). (TR 72) (TR64)
Source:
Active Unit Load Device (Active ULD)
A Unit Load Device (ULD) container used to consolidate cargo on aircraft that contains electrical or battery-powered temperature control systems for transporting temperature-sensitive materials; an RKN type is used in an FMEA example. (TR58) A unit load device with an active heating and/or cooling system that is typically used in air transportation, usually operated from externally supplied AC or DC power or from internal batteries. (TR64)
Source:
Active Unit Load Device (ULD)
A Unit Load Device (ULD) container used to consolidate cargo on aircraft that contains electrical or battery-powered temperature control systems for transporting temperature-sensitive materials; an RKN type is used in an FMEA example. (TR58) A unit load device with an active heating and/or cooling system that is typically used in air transportation, usually operated from externally supplied AC or DC power or from internal batteries. (TR 64)
Source:
Air Removal Test
A test used to evaluate air removal and steam penetration in an empty sterilizer that is used for porous/hard goods load sterilization (e.g., Bowie-Dick Test, DART, Lantor Cube, Browns’ Test). (TR01) (TR 48)
Source:
Airlock
A room that controls the airflow between two rooms of different classification. (TR 70)
Source:
Amplicon
A segment of double stranded DNA formed as the product of polymerase chain reaction or other amplification based techniques such as TMA or NASBA. (TR50)
Source:
Anaerobe
An organism that has the ability to grow in the absence of oxygen. (TR51)
Source:
Ancillary Packaging Components/Systems
Additional means used in combination with the basic transportation unit to maintain the required temperature during transport. Examples include active systems and passive systems. (TR39)
Source:
Aseptic Processing Simulation (APS)
A means for establishing the capability of an aseptic process as performed using a growth medium. (TR22) (TR62)
Source:
Attribute
A physical, chemical, or microbiological property or characteristic of an input or output material. (TR60)
Source:
Attributes (Process Performance Attribute)
An output variable or outcome that cannot be directly controlled, but is an indicator that the process performed as expected.(Synonym - Process Performance Parameter) (TR60)
Source:
Attributes (Quality Attribute)
A molecular or product characteristic that is selected for its ability to indicate the quality of the product. Collectively, the quality attributes define identity, purity, potency and stability of the product, and safety with respect to adventitious agents. Specifications measure a selected subset of the quality attributes. (TR60)