PDA Technical Reports are highly valued membership benefits because they offer expert guidance and opinions on important scientific and regulatory topics and are used as essential references by industry and regulatory authorities around the world. These reports include terms which explain the material and enhance the reader’s understanding.

The database presented here includes the glossary terms from all current technical reports. The database is searchable by keyword, topic, or by technical report. Each definition provided includes a link to the source technical report within the  PDA Technical Report Portal.

(Please select "All" to restart a filtered Search)

Air Removal Test
A test used to evaluate air removal and steam penetration in an empty sterilizer that is used for porous/hard goods load sterilization (e.g., Bowie-Dick Test, DART, Lantor Cube, Browns’ Test). (TR01) (TR 48)
Source:
Cool-Down Phase
The phase of a sterilization cycle that occurs after completion of the exposure phase. Parameters of a cool-down phase are typically defined in order to meet applicable user requirements for load cooling and drying. (TR01) The phase of a sterilization cycle that occurs after completion of the exposure phase. [Synonym: post-conditioning phase, slow exhaust phase, drying phase, equalization phase] (TR48) The phase of an SIP cycle that occurs after completion of the exposure phase. Parameters (e.g., time, temperature, pressure) of a cool-down phase are typically defined in order to meet applicable user requirements for system cooling and drying. (TR61)
Source:
Cycle Phases
A discrete series of sterilizer process steps (such as, heat-up, exposure and cool-down) performed sequentially that represent a complete sterilization cycle. (TR48)
Source:
Discrete Control Valve
A device designed for on/off operation; fully opened or fully closed. (TR48)
Source:
Dryness Fraction
An absolute measure of the actual latent heat of a sample of steam relative to the theoretical latent heat of saturated steam. (TR01) (TR48)
Source:
Eductor
A device that produces vacuum by means of the Venturi effect. [Synonym: Aspirator, ejector pump] (TR48)
Source:
F-Value (Lethality Factor)
A measurement of sterilization effectiveness, the F-value is the calculated equivalent lethality (using a specified z-value), in terms of minutes at a reference temperature (Tref), delivered by a sterilization cycle. (TR1) (TR3) (TR30) (TR48) (TR61)
Source:
Gravity Displacement
A sterilization process based on the principle that cold air within the chamber is heavier than the steam entering and will sink to the bottom of the chamber. As steam enters the chamber, air is pushed out the bottom drain and exits, with the condensate, through a steam trap. (TR01) (TR48) (TR61)
Source:
Heat Transfer
Energy that is transferred as a result of a temperature difference between an object and its surroundings. (TR48)
Source:
Heat-up Phase
The phase of a sterilization cycle that occurs prior to the exposure phase. Process parameters are developed for this phase in order to meet applicable user requirements for load conditioning (e.g., air removal and preheating.) (TR01) (TR3) (TR48) (TR61)
Source:
Installation Qualification (IQ)
Documented verification that the equipment or systems, as installed or modified, comply with the approved design, the manufacturer’s recommendations, and/or user requirements. (TR14) (TR42) (TR48) (TR61) (TR64) The documented verification that the facilities, systems and equipment, as installed or modified, comply with the approved design and the manu­facturer’s recommendations. (TR54-5) Documented verification that the equipment or systems, as installed or modified, comply with the approved design, the manufacturer’s recommendations, and/or user requirements (17). (TR60)
Source:
Liquid Load
A load consisting of closed containers of aqueous liquids. The sterilization of the container contents is achieved through transfer of energy through the container into the aqueous liquid. (TR01) (TR30) (TR48)
Source:
Load Zone
Area within the sterilization chamber where materials to be sterilized may be placed. (TR01) (TR3) (TR48)
Source:
Maximum Load
The maximum quantity or mass of items permitted in a sterilizer load. (TR01) The maximum quantity or mass of items permitted in a depyrogenation or sterilization load. (TR3) The maximum quantity or mass of products permitted in a validated sterilizer load. (TR30)The maximum quantity or mass of items permitted in a sterilizer load. (TR48)
Source:
Piping and Instrumentation Diagram (P&ID)
A schematic diagram that shows the relational arrangement of piping, components, instruments, and equipment connections of the system. It also illustrates the control and functional relationship. (TR48)
Source:
Proportional Control Valve
A device that is designed for precise positioning and continuous movement, typically in response to a varying analog signal. [Synonym: Modulating Valve] (TR48)
Source:
Saturated Steam
Steam that is at a temperature and pressure that corresponds to the vaporization curve of water. It is in a state of equilibrium between being a liquid and a gas, with no entrained liquid water. [Synonym: Dry Saturated Steam] (TR01) (TR48) (TR61)
Source:
Steam: Plant Steam
Steam of undefined chemical or biological quality produced from a boiler, usually containing boiler additives, without further treatment. [Synonym: Factory Steam, House Steam, Industrial Steam] (TR48)
Source:
Steam: Process Steam
Process steam is similar to plant steam, except the steam is generated using a controlled feed water source to which no volatile additives (amines or hydrazines) have been introduced. Process steam may be appropriate for moist heat sterilization of liquid loads where the containers are filled and sealed prior to sterilization. (TR48)
Source:
Steam: Pure Steam
Collected condensate that complies with the Compendial requirements for Water for Injecton (WFI). [Synonyms: clean steam, high quality steam] (TR01) (TR61) (TR48)
Source:
Sterilization Cycle
A sequence of defined operating parameters (e.g., time, temperature and pressure) and conditions required to render an item sterile. (TR01) (TR30) (TR48) A sequence of defined operating parameters (e.g., time and temperature) required to render an item sterile. (TR3)
Source:
Sterilizer Specification
Documents that define sterilizer system attributes and how they should be met. (TR48)
Source:
Sterilizer Specification (Design Specification (DS))
A set of specifications and information related to the installation features including equipment, hardware and software) of the system that will ensure the realization of the user requirements. [Synonym: Detailed Design Specification (DDS] (TR48)
Source:
Sterilizer Specification (User Requirement Specification (URS))
A description of features and performance requirements of a system that will fulfill the needs of the end user. (TR48)
Source:
Temperature Distribution
Temperature measurement of the heating medium (e.g., forced hot air) across the chamber load zone. (TR01) (TR03) (TR30) (TR48)
Source:
Temperature Probe/Sensor
A generic term used to describe any type of temperature measuring device that works through contact with the material or atmosphere to be measured. [Synonyms: Load Probe, Heat Penetration Probe, Temperature Distribution Probe, Drain Probe] (TR48)
Source: