PDA Technical Reports are highly valued membership benefits because they offer expert guidance and opinions on important scientific and regulatory topics and are used as essential references by industry and regulatory authorities around the world. These reports include terms which explain the material and enhance the reader’s understanding.

The database presented here includes the glossary terms from all current technical reports. The database is searchable by keyword, topic, or by technical report. Each definition provided includes a link to the source technical report within the  PDA Technical Report Portal.

(Please select "All" to restart a filtered Search)

  • All
  • 0
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • A
  • B
  • C
  • D
  • E
  • F
  • G
  • H
  • I
  • J
  • K
  • L
  • M
  • N
  • O
  • P
  • Q
  • R
  • S
  • T
  • U
  • V
  • W
  • X
  • Y
  • Z
Action Level (environmental monitoring)
An established microbial or non-viable particle level that, when exceeded, should trigger appropriate investigation and corrective action based on the investigation. (TR22)
Source:
Action Limit
An internal (in-house) value used to assess the consistency of the process. The cause of the excursion should be investigated and documented and corrective action is generally required. Action limits are not specifications. (TR42) An established internal (in-house) data-based value which is part of the control strategy and used to assess the consistency of the manufacturing process. An action limit excursion result in an investigation, identification of recovered isolates, root-cause analysis, assessment of a systemic failure and impact on product quality and patient safety. (TR69) An established internal (in-house) data-based value that is part of the control strategy and used to assess the consistency of the manufacturing process. An action limit excursion result in an investigation, identification of recovered isolates, root-cause analysis, assessment of a systemic failure and impact on product quality and patient safety. (TR74) A limit that, when exceeded, indicates a process is outside of its normal operating range. A response to such an excursion should involve a documented investigation and corrective actions based on the results of that investigation. (TR60)
Source:
Aerobic Microorganism
A microorganism that utilizes oxygen as the final electron acceptor during metabolism; a microorganism that will grow primarily in the presence of oxygen. For the purpose of this report, this definition encompasses facultative anaerobes. (TR22) (TR62)
Source:
Alert Level
An established microbial or nonviable particle level giving early warning of potential drift from normal operating conditions; not necessarily grounds for definitive corrective action but typically requires follow-up investigation. (TR13) (TR22) (TR69) An established level that, when exceeded, is giving an early warning of a potential drift from normal operating conditions; while not necessarily grounds for definitive corrective action, it typically requires follow-up review. (TR 60) An established microbial or nonviable particle level giving early warning of potential drift from normal operating conditions; not necessarily grounds for definitive corrective action, but typically requires follow-up investigation (3, 4, 7). (TR88)
Source:
Aseptic Processing
Handling sterile materials in a controlled environment, in which the air supply, facility, materials, equipment and personnel are regulated to control microbial and particulate contamination to acceptable levels. (TR28) (TR62) (TR69) Handling of sterile product, containers, and/ or devices in a controlled environment in which the air supply, materials, equipment, and personnel are regulated to maintain (product) sterility. (TR13)
Source:
Aseptic Processing Area (APA)
Controlled environment, consisting of several zones, in which the air supply, facility, materials, equipment and personnel are regulated to control microbial and particulate contamination to acceptable levels. (TR22) (TR28) (TR62) (TR70)
Source:
Aseptic Processing Simulation (APS)
Attachment (Adhesion)
Discrete association of a microorganism with an animate or inanimate surface. (TR69)
Source:
Dynamic (in operation)
BFS machine line fully operational and filling, with the number of allowed operating personnel present as during normal running conditions. (TR77)
Source:
Integrity Test
Test to determine the functional performance of a membrane filter or container/closure system. (TR22) A nondestructive test used to predict the functional performance of a filter. (TR45) A nondestructive physical test that can be correlated to the bacterial retention capability of a filter/filter assembly. (TR26)
Source:
Integrity Testing
A method of determining if a membrane or filter is physically intact and free from gross defects. (TR15)
Source:
Lenticular Filters
A filter made up of a series of biconvex cells that are stacked on top of one another with rings between them to prevent bypass between the cells. End-caps are then placed at the top and bottom of the assembly and are held in place with a central core. [Synonyms: Lenticular Cartridge, Modules, Filter Elements, Filter Devices] (TR45)
Source:
Log Reduction
Log reduction is defined as the first log being 90%, the second log being 9% and the third log being 0.09% of the original inoculums. (TR70)
Source:
Mandrel
Microfiltration (MF)
Pressure-driven, membrane-based separation process in which particles and dissolved macromolecules (typically 0.1 &mum or larger) are retained. (TR15)
Source:
Mollicutes
A class of bacteria which lack a cell wall. Mollicutes are small, typically about 0.1-0.5 &mum in size, and vary in form (trivial name: mycoplasma) (TR50)
Source:
Most Probable Number (MPN) Method
A statistical method of estimating the number of viable organisms suspended in a liquid. (TR51)
Source:
Negative Control
A test article used to assess the performance of an assay in the known absence of a targeted microorganism or nucleic acid. Negative controls are used to minimize a risk of false positive results, which could occur due to non-specific signals. (TR50)
Source:
Nonspecific Model Virus
A virus used for characterization of viral clearance of the process when the purpose is to characterize the capacity of the manufacturing process to remove and/or inactivate viruses in general (i.e., to characterize the general viral clearance capacity of the purification process.) (TR41)
Source:
Parison
Stirred-Cell Filtration
A surrogate for tangential flow filtration where shear is achieved by rapidly stirring the solution immediately adjacent to the membrane. Typically the stirring is accomplished by mechanical means, such as through the use of a stir bar or impeller. (TR15)
Source: