
PDA Technical Glossary
PDA Technical Reports are highly valued membership benefits because they offer expert guidance and opinions on important scientific and regulatory topics and are used as essential references by industry and regulatory authorities around the world. These reports include terms which explain the material and enhance the reader’s understanding.
The database presented here includes the glossary terms from all current technical reports. The database is searchable by keyword, topic, or by technical report. Each definition provided includes a link to the source technical report within the PDA Technical Report Portal.
(Please select "All" to restart a filtered Search)
Refine Results
Filter By Technical Report Number
- TR 13: Environmental Monitoring (2)
- TR 22: Aseptic Process Simulation (2)
- TR 56: Phase Appropriate cGMP Application (1)
- TR 57: Analytical Method Validation (1)
- TR 60: Process Validation (1)
- TR 74: Reprocessing of Biopharmaceuticals (1)
- TR 14: Validation: Protein Purification Chromatography (1)
- TR 38: Manufacturing Chromatography Systems Postapproval Changes (ChromPAC) (1)
- TR 60-3: Process Validation: A Lifecycle Approach: Bio Drug Sub Mfg (1)
Filter By Technical Report Keyword
Filter By Technical Report Category
Action Level
An established microbial or airborne particle level that, when exceeded, indicates a process is outside of its normal operating range. A response to such an excursion should involve a documented investigation and corrective actions based on the results of that investigation. (TR13)
An established microbial or non-viable particle level that, when exceeded, should trigger appropriate investigation and corrective action based on the investigation. (TR22)
An established microbial or airborne particle level for environmental, water or gas monitoring that, when exceeded, indicates that a facility process is outside of its normal operating range. The response to such an excursion involves a documented investigation and corrective actions based on the results of that investigation. The prescribed action level is often specified in guidance or standards relating to environmental monitoring and water quality. (TR69)
An established microbial or nonviable particle level for environmental, water, or gas monitoring that, when exceeded, indicates a facility or process is outside of its normal operating range. The response to such an excursion may involve a documented investigation and corrective actions based on the results. The prescribed action level is often specified in guidances or standards relating to environmental monitoring and water quality (3-6). (TR88)
Source:
Alert Level
An established microbial or nonviable particle level giving early warning of potential drift from normal operating conditions; not necessarily grounds for definitive corrective action but typically requires follow-up investigation. (TR13) (TR22) (TR69)
An established level that, when exceeded, is giving an early warning of a potential drift from normal operating conditions; while not necessarily grounds for definitive corrective action, it typically requires follow-up review. (TR 60)
An established microbial or nonviable particle level giving early warning of potential drift from normal operating conditions; not necessarily grounds for definitive corrective action, but typically requires follow-up investigation (3, 4, 7). (TR88)
Source:
Specification
A list of tests, references to analytical procedures, and appropriate acceptance criteria that are numerical limits, ranges, or other criteria for the test described. It establishes the set of criteria to which a material should conform to be considered acceptable for its intended use. (TR14)
A list of tests, references to analytical procedures, and appropriate acceptance criteria that are numerical limits, ranges, or other criteria for the test described. It establishes the set of criteria to which a material should conform to be considered acceptable for its intended use. Drug product and drug substance specifications are critical quality standards that are proposed and justified by the manufacturer and approved by regulatory authorities (TR38) (TR57)
A list of tests, references to analytical procedures, and appropriate acceptance criteria that are numerical limits, ranges, or other criteria for the test described. It establishes the set of criteria to which a material should conform to be considered acceptable for its intended use. Drug product and drug substance specifications are critical quality standards that are proposed and justified by the manufacturer and approved by regulatory authorities (TR69)
A list of tests, references to analytical procedures, and appropriate acceptance criteria, which are numerical limits, ranges, or other criteria for the tests described. It establishes the set of criteria to which a drug substance, drug product, or materials at other stages of its manufacture should conform to be considered acceptable for its intended use. “Conformance to specification” means that the drug substance and drug product, when tested according to the listed analytical procedures, will meet the acceptance criteria. Specifications are critical quality standards that are proposed and justified by the manufacturer and approved by regulatory authorities as conditions of approval. (TR56) (TR74)
A list of tests, references to analytical procedures, and appropriate acceptance criteria that are numerical limits, ranges, or other criteria for the test described. It establishes the set of criteria to which a material should conform to be considered acceptable for its intended use (17). (TR60-3)(TR88)