PDA Technical Glossary
PDA Technical Reports are highly valued membership benefits because they offer expert guidance and opinions on important scientific and regulatory topics and are used as essential references by industry and regulatory authorities around the world. These reports include terms which explain the material and enhance the reader’s understanding.
The database presented here includes the glossary terms from all current technical reports. The database is searchable by keyword, topic, or by technical report. Each definition provided includes a link to the source technical report within the PDA Technical Report Portal.
(Please select "All" to restart a filtered Search)
Refine Results
Filter By Technical Report Number
- TR 60: Process Validation (3)
- TR 14: Validation: Protein Purification Chromatography (3)
- TR 56: Phase Appropriate cGMP Application (2)
- TR 57: Analytical Method Validation (2)
- TR 69: Bioburden/Biofilm Management (2)
- TR 29: Validation: Cleaning (2)
- TR 48: Moist Heat Sterilizer Systems (1)
- TR 54: QRM:Manufacturing Operations (1)
- TR 54-3: QRM: Drug Products (1)
- TR 54-4: QRM: Biotech Drug Substance (1)
- TR 63: Clinical Trials Material Preparation (1)
- TR 64: Temp Controlled Systems Qualification (1)
- TR 70: Cleaning/Disinfection Programs (1)
- TR 72: Passive Thermal Protection Systems: Qualification/Operations (1)
- TR 38: Manufacturing Chromatography Systems Postapproval Changes (ChromPAC) (1)
- TR 60-3: Process Validation: A Lifecycle Approach: Bio Drug Sub Mfg (1)
- TR 60-2: Process Validation: A Lifecycle Approach, Annex 1: Oral Solid Dosage/Semisolid Dosage Forms (1)
- TR 54-5: Quality Risk Management for the Design, Qualification, and Operation of Manufacturing Systems (1)
- TR 41: Virus Filtration (1)
- TR 44: QRM: Aseptic Processes (1)
Filter By Technical Report Keyword
Filter By Technical Report Category
Acceptance Criteria
Numerical limits, ranges, or other suitable measures for acceptance of test results. (TR 14) (TR 29) (TR 38) (TR 64)
Numerical limits, ranges, or other suitable measures for acceptance of test results. Exceeding the acceptable range for a critical parameter during subsequent validation studies may result in questionable product quality that would require initiation of an investigation. Exceeding the operating range should be documented and explained in the validation report and evaluated for validation study impact. (TR 42)
The pre-defined specifications, standards or ranges that must be met under stated test conditions. (TR 48)
Numerical limits, ranges, or other suitable measures for acceptance of the results of analytical method validation that is satisfied to determine suitability of test method performance.(TR 57) (TR 69) (TR 72) (TR 74)
The criteria that a system or component must satisfy in order to be accepted by a user or other authorized entity. (TR 54-5)
Numerical limits, ranges, or other suitable measures for acceptance of the results of analytical procedures which the drug substance or drug product or materials at other stages of their manufacture should meet (16). Exceeding the acceptable range for a critical parameter during subsequent validation studies may result in questionable product quality that would require initiation of an investigation and possible batch rejection. (TR60)
Source:
Action Limit
An internal (in-house) value used to assess the consistency of the process. The cause of the excursion should be investigated and documented and corrective action is generally required. Action limits are not specifications. (TR42)
An established internal (in-house) data-based value which is part of the control strategy and used to assess the consistency of the manufacturing process. An action limit excursion result in an investigation, identification of recovered isolates, root-cause analysis, assessment of a systemic failure and impact on product quality and patient safety. (TR69)
An established internal (in-house) data-based value that is part of the control strategy and used to assess the consistency of the manufacturing process. An action limit excursion result in an investigation, identification of recovered isolates, root-cause analysis, assessment of a systemic failure and impact on product quality and patient safety. (TR74)
A limit that, when exceeded, indicates a process is outside of its normal operating range. A response to such an excursion should involve a documented investigation and corrective actions based on the results of that investigation. (TR60)
Source:
Active Pharmaceutical Ingredient (API)
Synonym: Drug Substance. (TR14) (TR42) A substance or mixture of substances that, when delivered in a finished drug product, directly affects the structure or function of the body. (TR54-4) Any substance or mixture of substance intended to be used in the manufacture of a drug (medicinal) product and that, when used in the production of a drug, becomes an active ingredient of the drug product. Such substances are intended to furnish pharmacological activity or other direct effect in the diagnosis, cure, mitigation, treatment, or prevention of disease or to affect the structure and function of the body. Note: also known as Drug Substance. (TR29) (TR56) (TR41) (TR54-3) (TR60) Any substance or mixture of substances intended to be used in the compounding of a drug preparation, thereby becoming the active ingredient in that preparation and furnishing pharmacological activity o other direct effect in the diagnosis, cure, mitigation, treatment, or prevention of disease in humans and animals or affecting the structure and function of the body. (TR63) (TR70) Any substance or mixture of substances intended to be used in the manufacture of a drug product, and that when used in the production of a drug, becomes an active ingredient in the drug product. Such substances are intended to furnish pharmacological activity or other direct effect in the diagnosis, cure, mitigation, treatment or prevention of disease, or to affect the structure and function of the body. (TR74)
Source:
Process Validation
The documented evidence that the process, operated within established parameters, can perform effectively and reproducibly to produce an intermediate or API (drug substance) meeting its predetermined specifications and quality attributes. (TR14) (TR42)
Establishing documented evidence which provides a high degree of assurance that a specific process will consistently produce a product meeting its predetermined specifications and quality attributes. (TR44)
The collection and evaluation of data, from the process design stage through commercial production, which establishes scientific evidence that a process is capable of consistently delivering quality products. (TR54) (TR57) (TR74)
The collection and evaluation of data, from the process design stage through commercial production, which establishes scientific evidence that a process is capable of consistently delivering quality product.
The documented evidence that the process, operated within established parameters, can perform effectively and reproducibly to produce a medicinal product meeting its predetermined specifications and quality attributes, as described in EMA, EU GMP, Part 1, Annex 15, drug/medicinal product. (TR56)
EMA: The documented evidence that the process, operated within established parameters, can perform effectively and reproducibly to produce a medicinal product meeting its predetermined specifications and quality attributes.
US FDA: The collection and evaluation of data, from the process design stage through commercial production, which establishes scientific evidence that a process is capable of consistently delivering quality products. (TR60-2)
The documented evidence that the process, operated within established parameters, can perform effectively and reproducibly to produce an intermediate or drug substance meeting its predetermined specifications and quality attributes (1, 17). (TR60-3)