PDA Technical Glossary

PDA Technical Glossary

PDA Technical Reports are highly valued membership benefits because they offer expert guidance and opinions on important scientific and regulatory topics and are used as essential references by industry and regulatory authorities around the world. These reports include terms which explain the material and enhance the reader’s understanding.

The database presented here includes the glossary terms from all current technical reports. The database is searchable by keyword, topic, or by technical report. Each definition provided includes a link to the source technical report within the  PDA Technical Report Portal.

(Please select "All" to restart a filtered Search)

  • All
  • 0
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • A
  • B
  • C
  • D
  • E
  • F
  • G
  • H
  • I
  • J
  • K
  • L
  • M
  • N
  • O
  • P
  • Q
  • R
  • S
  • T
  • U
  • V
  • W
  • X
  • Y
  • Z
Acceptable Quality Limit (AQL)
The quality level that is the worst-tolerable process average when a continuing series of lots are submitted for acceptance sampling. (TR43) (TR 76)
Source:
Attribute Sampling
Inspection where either the unit of product is classified as conforming or non-conforming or the number of non-conformities in the unit of products is counted with respect to a given requirement of set of requirements. (TR43)
Source:
Defect
(1) A departure of a quality characteristic from its intended level or state that occurs with a severity sufficient to cause an associated product or service not to satisfy its intended normal or foreseeable usage requirements. (TR51) (2) The nonfulfillment of intended usage requirements. The departure or absence of one or more quality characteristics from intended usage requirements. (TR43)
Source:
Incoming Inspection
A preventative program where parts or products are subjected to evaluation upon receipt.(TR43) A program where, upon receipt, parts or products are subjected to measuring, examining, testing, or gauging one or more characteristics of a product or service, and comparing the results with specified requirements in order to establish whether conformity is achieved for each characteristic.(TR 76)
Source:
Online Observations
Observations or findings that are found during the processing of a product or products. (TR43)
Source:
Operating Characteristic Curves
The operating characteristic curve shows the probability of acceptance (Pa) for any level of lot quality. (TR43)
Source:
Post-fill Inspection
Product Stream
The process flow in which a product is manufactured.(TR43) The process flow in which a product is manufactured that is often described in a process map.(TR 76)
Source:
Quality Risk Management (QRM)
A systematic process for the assessment, control, communication, and review of risk to the quality of the drug product across the product lifecycle.(TR43)(TR54-2)(TR54-3)(TR57)(TR67)(TR68) Documentation to prove that an installation/ equipment/process is designed and/or tested according to predefined specifications. Documentation may include Design Qualification (DQ), Installation Qualification (IQ), Operational Qualification (OQ) and Performance Qualification (PQ).(TR58) A systematic process for the assessment, control, communication, and review of risks to the quality of the drug (medicinal) product across the product lifecycle.(TR 54-5)(TR 76)(TR88)
Source:
Quality Specification System
Sampling Plan
This indicates the number of units of product from each lot or batch which are to be inspected (sample size or series of sample sizes) and the criteria for determining the acceptability of the lot or batch (acceptance and rejection numbers). (TR43) The number of units of product from each lot or batch that need to be inspected (sample size or series of sample sizes) and the criteria for determining the acceptability of the lot or batch (acceptance and rejection numbers). (TR 76)
Source:
Sanitization
Reduction of microbial contaminants to safe levels as judged by public health requirements for the specific country. (TR13) A significant reduction in bioburden, achieved in chromatography by the use of bactericidal agents, such as sodium hydroxide (NaOH), hydrochloric acid (HCl), ethanol (EtOH), and isopropanol (IPA). (TR14) The process of reducing microbial levels by treatment at less than defined sterilizing conditions. Typically water at 80 °C or a chemical treatment is used to perform sanitization of process components. (TR45) A process that reduces the number of viable microorganisms to a defined level. (TR61) (TR69)
Source: