PDA Technical Glossary
PDA Technical Reports are highly valued membership benefits because they offer expert guidance and opinions on important scientific and regulatory topics and are used as essential references by industry and regulatory authorities around the world. These reports include terms which explain the material and enhance the reader’s understanding.
The database presented here includes the glossary terms from all current technical reports. The database is searchable by keyword, topic, or by technical report. Each definition provided includes a link to the source technical report within the PDA Technical Report Portal.
(Please select "All" to restart a filtered Search)
Refine Results
Filter By Technical Report Number
- TR 46: Good Distribution: Last Mile (1)
- TR 55: TBA/TCA Detection Mitigation (1)
- TR 57: Analytical Method Validation (1)
- TR 58: Temp Controlled Distribution (1)
- TR 63: Clinical Trials Material Preparation (1)
- TR 64: Temp Controlled Systems Qualification (1)
- TR 86: Industry Challenges and Current Technologies for Pharmaceutical Package Integrity Testing (1)
Filter By Technical Report Keyword
Manufacturing
The production, packing, testing, storage, release and distribution of drugs or medical devices for use in humans or animals where the manufacturing is indented to produce doses, typically in significant numbers, for an undefined population of future patients or clinical trial subjects. (TR63)
All operations including purchasing and receipt of materials to production, packaging, labelling, quality control, release, storage, distribution of components and the related controls. (TR 76)
Source:
Maximum Allowable Leak Limit (MALL)
The greatest gap or leak rate that does not put product quality at risk (2). (TR86)
Source:
Mean Kinetic Temperature (MKT)
The single calculated temperature at which the total amount of degradation over a particular period is equal to the sum of the individual degradations that would occur at various temperatures. Thus, MKT may be considered as an isothermal storage temperature that simulates the nonisothermal effects of storage temperature variation. It is not a simple arithmetic mean. (TR46) (TR58)
Source:
Method Comparability
The demonstration of analytical method comparability (AMC) for method replacements. A study to demonstrate that a modification to an existing method either improves or does not significantly change the analytical procedure’s characteristics relative to the methods’ validation and intended use. (TR57)
Source:
Microprocessor
One of the five major components of a TCU, the unit interfaces with temperature sensors in the discharge and return air and adjusts the output rate of active cooling or heating to achieve the setpoint temperature. (TR64)
Source:
Moisture Content of Wood
The moisture content of wood is calculated by the following formula: Moisture content = (Mg-Mod)/Mod. Where Mg is the green mass of the wood and Mod is its oven-dry mass (the attainment of constant mass generally after drying in an oven set at 103 ± 2 °C for 24h). The equation can also be expressed as a fraction of the mass of the water and the mass of the oven-dry wood rather than a percentage. For example, 0.59 kg/kg (oven-dry basis) expresses the same moisture content as 59% (oven-dry basis). (TR55)