Glossary Terms (Simple List)
-
Color Changing Unit (CCU)
The quantity of mycoplasma contained in the highest dilution of a test article that produces a color change in a pH-sensitive liquid medium (typically containing phenol red) within a specified time of incubation, used for end-point determination of growth. (TR50)
-
Column Load
The solute that is passed through the column for separation. (TR14)
-
Column Packing
Preparation of a column that includes the addition of resin slurry into a column to create a bed suitable for its intended use. Characteristics of a packed column bed include bed height and diameter, backpressure, and number of theoretical plates. (TR14)
-
Commissioning
A well planned, documented and managed engineering approach to the start-up and transfer of facilities, systems and equipment to the end-user that results in a safe and functional environment that meets established design and user requirement specifications. Commissioning precedes Qualification and includes three phases:
1. Inspection, testing, and regulation
2. Adjustment and setting of work
3. Functional testing (TR 3)A prescribed number of activities designed to take equipment and systems from a static, substantially complete state to an operable state. (TR 48)
A well planned, documented, managed engineering approach to the start-up and turnover of facilities, systems, and equipment to the end-user, that results in a safe and functional environment that meets established design requirements and stakeholder expectations.(TR 54) (TR 54-5)
-
Common Carrier
Transportation available to the public that does not provide special treatment to any one party and is regulated as to the rates charged, the liability assumed, and the service provided. A common carrier must obtain a certificate of public convenience and necessity from the Federal Trade Commission for interstate traffic. (TR46)
-
Comparability
The quality or state of being suitable for comparison. FDA may determine that two products are comparable if the results of the comparability testing demonstrate that a manufacturing change does not affect identity, strength, quality, purity, or potency as they may relate to the safety or effectiveness of the product. (TR38)
-
Comparability Protocol
A protocol submitted by an applicant under CFR 601.12(e) and 314.70 (g) that describes the specific tests and validation studies and acceptable limits to be achieved to demonstrate the lack of adverse effect for specified types of manufacturing changes on the identity, strength, quality, purity, and potency of the product as they may relate to the safety or effectiveness of the product. Any such protocols, or change to a protocol, shall be submitted as a supplement requiring approval from FDA prior to distribution of the product. The supplement, if approved, may justify a reduced reporting category for the particular change because the use of the protocol for that type of change reduces the potential risk of an adverse effect. (TR38)
-
Comparability Study
An assessment of the similarities between the critical parameters and output results of two or more separate processes or methods. (TR50)
-
Comparative Transfer
Transfer of a method that involves the analysis of a predetermined number of samples of the same lot by both the sending and the receiving unit. (TR 57-2)
-
Compatibility
Proof that no adverse interaction between the filter and the process fluid has occurred. (TR26)
A term used in relation to the non-reactivity of filter materials with the substance to be filtered. (TR45)