Glossary Terms (Simple List)
-
Endotoxin
Lipopolysaccharides from the cell walls of bacteria, the most potent of which derive from Gram-negative organisms. When injected, they are known to cause a febrile, or fever-producing reaction that can cause severe patient reactions, and on occasion, can be fatal. (TR26) (TR44)
Pyrogenic lipopolysaccharide component of Gram-negative bacterial cell walls. (TR69)
-
Endotoxin Indicator (EI) for Depyrogenation
An article challenged with a vial of endotoxin (or a carrier spiked with endotoxin) designed for use in depyrogenation studies. The endotoxin (a purified lipopolysaccaride) is validated for use in or on an endotoxin indicator. The carrier is made from a material appropriate for the intended depyrogenation processes to which it will be subjected. The endotoxin on a carrier is added at a concentration sufficient to allow recovery of a minimum of 1000 USP endotoxin units/carrier. The endotoxin indicator would allow for accurate indication of at least a 3-log reduction in USP endotoxin units during depyrogenation process challenges. (TR3)
-
Endpoint PCR
A classical PCR method based on repeated cycling of the reaction mixture between two or three temperatures (denaturing, annealing, and extension) with detection of the amplified product after reaction completion (e.g., by agarose gel electrophoresis). (TR50)
-
Environmental Control Parameters
Conditions and corresponding measurements as associated with facilities and equipment used in the control of a manufacturing area that may impact the identity, strength, quality, or purity of a product. Among such parameters are airflow rates and patterns, pressure differentials, materials and personnel flow, temperature and relative humidity, as well as nonviable and viable particulates. (TR13)
-
Environmental Flora (isolates)
Microorganisms associated with a processing environment. (TR22)
-
Environmental Monitoring (EM)
Describes the processes and activities that need to take place to characterize and monitor the quality of the environment. (TR70)
Monitoring for nonviable particulates and/or microorganisms where the result meets or exceeds the alert and/or action level or limit. (TR88)
-
Environmental Monitoring Program
Defined documented program which describes the routine particulate and microbiological monitoring of processing and manufacturing areas, and includes a corrective action plan when action levels are exceeded. It includes assessment of environmental air, surfaces and personnel. (TR22) (TR28) (TR62)
-
Enzyme-Linked Immunosorbent Assay, or ELISA
A biochemical technique used to detect or measure the presence of an antibody or an antigen in a sample. (TR41) (TR47)
-
Equilibration
Column washing with a solution or buffer(s) in preparation for the column load. (TR14)
-
Equilibration Time
The period that elapses between the attainment of the minimum exposure temperature at the reference measurement point (typically the drain) and the attainment of the sterilization temperature at all points within the load. This period is an indication of the ability to properly remove air and heat the load items; consequently, it is typically only evaluated by placing heat penetration probes in porous/hard goods loads. (TR01) (TR48)